ASN AQ ASV Flow Rate and Sonic Conductance Symbol AK AS221F-01 AS121F-M5 AS221F-02 AS321F AS421F Model Tubing O.D.
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5
Millimeter Inch With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 01 03 05 07 09 11 4 6 8 10 12 04 06 08 10 12 Thread _ Meter thread (M5) Unified thread (10-32 UNF) R(PT) N NPT Port size M5 X 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AS ASN AQ ASV Needle Valve/Flow Characteristics AK ASD230F ASD330F ASD430F ASS 100 200 400 1.5 6 3 07, 08, 09, 10, 11 Effective area (mm2) Flow
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
HRL300-A-40 CH1 . 9-13 9.4.4 HRL100/200/300-A-40 CH2 . 9-13 9.4.5 HRL100-A-40-T2 CH1 . 9-14 9.4.6 HRL200-A-40-T2 CH2 . 9-14 9.4.7 HRL300-A-40-T2 CH1 . 9-15 9.4.8 HRL100/200/300-A-40-T2 CH2 . 9-15 9.4.9 HRL300-A-40-T3 CH1 . 9-16 9.4.10 HRL300-A-40-T3 CH2 . 9-16 9.4.11 HRL100-W-40 CH1 . 9-17 9.4.12 HRL200-W-40 CH1 . 9-17 9.4.13 HRL100/200-W-40 CH2 . 9-18 9.4.14 HRL100-W-40-T2 CH1 . 9-18 HRL
/250-W-20/40. 8-10 8.3 Flow Diagram . 8-11 8.3.1 HRSH-A-20/40. 8-11 8.3.2 HRSH-W-20/40. 8-12 8.4 Cooling Capacity . 8-13 8.4.1 HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250-W-20/40. 8-17 8.5 Pump Capacity
Can drive 40*1 bore cylinders Can drive 50*1 bore cylinders Can drive 80*1 bore cylinders JSY1000 JSY3000 JSY5000 6.4 mm 10 mm 15 mm A, B port size: 2, 4, 6 A, B port size: 6, 8 A, B port size: 10, 12 6 One-touch fitting 12 One-touch fitting 8 One-touch fitting 540 550 520 63 25 40 Bore size [mm] Bore size [mm] Bore size [mm] 360 310 430 80 40 50 100 140 110 160 63 100 100 300 500 100 300
: 4-48 32 : 1-12 65 : M5 x 0.8 93 : M30 x 3.5 05 : 5-40 33 : 1 1/8-7 66 : M6 x 0.75 94 : M36 x 4.0 06 : 5-44 34 : 1 1/8-12 67 : M6 x 1.0 95 : M16 x 1.25 07 : 6-32 35 : 1 1/4-7 68 : M8 x 1.0 96 : M36 x 1.5 08 : 6-40 36 : 1 1/4-12 69 : M8 x 1.25 97 : M36 x 2.0 09 : 8-32 37 : 1 3/8-6 70 : M10 x 1.25 10 : 8-36 38 : 1 3/8-12 71 : M10 x 1.5 11 : 10-24 39 : 1-14 72 : M12 x 1.5 12 : 10-32 40 : 1