SMC Corporation of America
Elite Part Number Search
Search Results "HRS050-AN-20-BJ"

Body Size: 20, Backflow: K (w/Backflow Function), Thread: Rc, Port Size: 02 (1/4), Options: BJ (B+J), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 20, Backflow: K (w/Backflow Function), Thread: F (G), Port Size: 01 (1/8), Options: BJ (B+J), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: BJ (w/ Earth Leakage Breaker + w/ Automatic Fluid Fill Function)


Alarm code “AL28” (pump maintenance) will be activated every 20,000 hours (every 8000 hours for option “T” and the HRS050/060) of operation.
Consider requesting maintenance from a maintenance company.
We can recommend service providers if needed.


For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.

Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030; SMC recommends Bypass Piping Set HRS-BP004 for Models HRS-040, HRS050

Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030; SMC recommends Bypass Piping Set HRS-BP004 for Models HRS-040, HRS050

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO-CHILLER, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 152.11896 lb

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)