Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: JM (J + M)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: JM (J + M)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: JM (J + M)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO-CHILLER, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 127.86811 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO-CHILLER, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 119.04962 lb
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.? An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.? An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Pump capacity 9.4.4 HRSH090-A-20/40-HRSH090-W-20/400.6 60 Circulating fluid pressure [MPa] 0.5 50 Pump head [m] 0.4 40 Outlet Usable flow rate range 0.3 30 Usable flow rate range 0.2 20 Return port 0.1 10 0 0 0 10 20 30 40 50 60 70 Circulating fluid flow [L/min] Fig. 9-8 Pump capacity (HRSH090-A-20/40-HRSH090-W-20/40-) 0 Pump capacity HRSH Series 9-12 HRX-OM-R026 Chapter 9 Documents 9.5
Model number: HRR050-AN/WN-20/40The transition connector from Rc to NPT is enclosed as an accessory. For NPT piping, be sure to use this connector. Model number: HRR050-AF/WF-20/40The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
. 9-1 9.1.2 HRS090-A-40. 9-2 9.1.3 HRS090-A-46. 9-3 9.1.4 HRS090-W-20. 9-4 9.1.5 HRS090-W-40. 9-5 9.1.6 HRS090-W-46. 9-6 9.1.7 Refrigerant with GWP reference . 9-7 9.1.8 Communication specification . 9-7 9.2 Outline dimensions . 9-8 9.2.1 HRS090-A-20/40/46-. 9-8 9.2.2 HRS090-W-20/40/46-. 9-9 9.3 Flow diagram . 9-10 9.3.1 HRS090-A-20/40/46-. 9-10 9.3.2 HRS090-W-20/40/46 . 9-10 9.4 Cooling
Mounting same side MG D-C7 D-C8 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-H7C 50+45(n2) 50 15 10 MGP 15+45( n2 ) (n=2, 4, 6) 2 60+45(n2) 60 15 10 MGQ 15+50( n2 ) (n=2, 4, 6) MGG 2 65 15 10 65+50(n2) 20+50( n2 ) (n=2, 4, 6) 2 MGC 65 20 D-H7LF 10 15+50( n2 ) (n=2, 4, 6) 2 D-B5/B6 D-G5NTL MGF 10 75 15 75+55(n2) 20+50( n2 ) (n=2, 4, 6) 2 15 MGZ D-B59W 75 20 D-A3A D-G39A D-K39A D-A44A CY 10 100