SMC Corporation of America
Elite Part Number Search
Search Results "HRS030-AN-20-BM"

Related products HRS01-A-10-, HRS01-W-10HRS050-A20-, HRS050-W-20HRS01-A-20-, HRS01-W-20HRS060-A-20, HRS050-W-20HRS024-A-20-, HRS024-W-20HRS030-A-20-, HRS030-W-20HRS040-A-20-, HRS040-W-20HRS050-A-20, HRS050-W-20HRS060-A-20, HRS050-W-202. Mounting This particle filter set includes the following parts.

GA GB 2-P Bore size A AL B1 H H1 MM ZZ W 10 M BM H1 20 14 12.7 11.0 25.4 4.0 1/4-28 108.4 25 14 12.7 12.6 28.4 4.8 5/16-24 111.4 Max.

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M

Form/Diameter Model Flat type with groove (UM) Bellows type with groove (BM) 32 40 50 63 80 100 125 32 40 50 63 80 100 125 ZP3EA-P1 V V V V ZP3EA-P2 V V ZP3EA-P3 V V V ZP3EA-P4 V V ZP3EA-P5 V V ZP3EA-P6 V Pad diameter 32 to 50 Pad form Flat type with groove Dimensions: Pad Unit ZP3E-32UMlZP3E-40UMlZP3E-50UMl36 31 27 27 23 20 27 23 20 10.3 (Plate) 10.3 (Plate) 10.3 (Plate) 13.5 13 13

Vacuum Pad with Ejector ZHP Series 63, 80 RoHS ZK2 How to Order ZQ ZHP 80 BM N B 00 Without ejector ZR ZB ZHP 80 BM N B 10 C6 S With ejector ZA Exhaust release Pad diameter ZX 63 63 80 80 S Silencer exhaust ZM Supply (P) port Pad form Symbol Type Port size C4 Metric 4 One-touch tting C6 6 One-touch tting N3 Inch 5/32" One-touch tting N7 1/4" One-touch tting BM Bellows type with groove UM

, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030

1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030

, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030

1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030

SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.

SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.

SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.

Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc

Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None