SMC Corporation of America
Elite Part Number Search
Search Results "HRS024-WN-20-BT"

-04 BT-04 BT-08 BT-08 BT-06 63 CC 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 RB 100 25 to 750 25 to 600 Up to 1100 Up to 850 BD1-04M BD1-05M BD1-08M BD1-10M BD1-06M (kg) Weight J 40 50 63 80 100 Bore size (mm) DBasic style 2.18 3.39 5.29 8.66 12.09 BA-04 BA-05 BA-08 BA-10 BA-06 Foot style 2.37 3.61 5.63 9.33 13.08 -X Flange style 2.55 3.84 6.08 10.11

-04 BT-04 BT-06 BT-08 BT-08 63 CC 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 RB 100 25 to 750 25 to 600 Up to 1100 Up to 850 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M (kg) Weight J 40 50 63 80 100 Bore size (mm) DBasic style 2.18 3.39 5.29 8.66 12.09 BA-04 BA-05 BA-06 BA-08 BA-10 Foot style 2.37 3.61 5.63 9.33 13.08 -X Flange style 2.55 3.84 6.08 10.11

Auto switch model Bore size (mm) 32 40 50 63 80 100 D-M9/ M9V D-M9W/ M9WV D-M9A/ M9AV D-A9/ A9V BMB5-032 BMB5-032 BA7-040 BA7-040 BA7-063 BA7-063 D-A3/ A44 D-G39/ K39 BMB2-032 BMB2-040 BMB1-050 BMB1-063 BMB1-080 BMB1-100 D-F5/ J59 D-F5W/ J59W D-F59F/ F5BA D-F5NT D-A5/ A6/ A59W BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 D-P3DWA BA10-032S BA10-040S BA10-050S BA10-050S BA10-063S BA10-063S D-P4DW BMB3T

Note) The minimum bending radius of the D sub connector cable is 20 mm. Insulation resistance Mkm, 20C (68F) 5 or more 16 44 8 SMC Connector manufacturers Fujitsu Ltd. Japan Aviation Electronics Industry, Ltd. J. S. T. Manufacturing Co., Ltd.

Note) The minimum bending radius of the D sub connector cable is 20 mm. Insulation resistance Mkm, 20C (68F) 5 or more 16 44 8 SMC Connector manufacturers Fujitsu Ltd. Japan Aviation Electronics Industry, Ltd. J. S. T. Manufacturing Co., Ltd.

, 100 Fiber 65 x L250 1, 5, 10, 20 5, 10, 20, 40 74, 105 Micromesh 65 x L250 Refer to pages 256 and 257 for the replacement element type.

, 100 Fiber 65 x L250 1, 5, 10, 20 5, 10, 20, 40 74, 105 Micromesh 65 x L250 Refer to pages 256 and 257 for the replacement element type.

Nil S n L Auto switch type Nil Without auto switch Cylinder bore size (stroke mm) Refer to the table below for auto switch part numbers. 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil F R Note 2) Standard With buffer With

mm Lead 150 Slide screw 20 mm Lead 500 10 mm Lead Ball screw Horizontal specification Maximum speed 1000 600 500 930 740 20 mm Lead 100W mm/s 500 Slide screw 20 mm Lead 180 10 mm Lead Ball screw 100W Nm Rated thrust 90 20 mm Lead 50 Slide screw 20 mm Lead Rolled 0.05 Repeatable positioning accuracy Ball screw Ground 0.02 mm 0.1 Rolled Slide screw Motor output Horizontal specification

Bore size (Stroke (mm)) 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 6 8 12 16 20 25 Functional option Standard With buffer With end lock Axial piping type With buffer and end lock With buffer, Axial piping type Nil F R (2) P FR (2) FP Adjuster option Note

52 : 1 3/4-12 85 : M24 x 1.5 25 : 5/8-11 53 : 1 3/4-5 86 : M26 x 1.5 26 : 5/8-18 54 :1 7/8-12 87 : M30 x 1.5 FEMALE ROD DIAMETER BORE (INCH) A B C MM KK WF 150 (1.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 200 (2) 3/4 1 1/8 3/8 5/8 7/16-20 1 250 (2.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 325 (3.25) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 400 (4) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 22 Air Cylinder Extended Series NCA1 PARTS

52 : 1 3/4-12 85 : M24 x 1.5 25 : 5/8-11 53 : 1 3/4-5 86 : M26 x 1.5 26 : 5/8-18 54 :1 7/8-12 87 : M30 x 1.5 FEMALE ROD DIAMETER BORE (INCH) A B C MM KK WF 150 (1.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 200 (2) 3/4 1 1/8 3/8 5/8 7/16-20 1 250 (2.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 325 (3.25) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 400 (4) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 22 Air Cylinder Extended Series NCA1 PARTS

W .TOea TT XIUS ' Z ZZ l ~/ t ~ ~ 20 27 Y. 42 11 20 45 153 8 15 !

40 20 14 15.5 19 to 600 32 75 18 104.5 58.5 63 1/4 12 45 17.5 35 27 11 75 134.5 56.5 14 20 40 20 14 16.5 23 to 600 32 90 18 119.5 68 80 1/4 18 45 22 40 32 13 95 169 72 22 30 60 25 20 19 33 to 750 37 102 22 150 81 100 1/4 20 55 25 40 41 16 114 189 89 22 30 60 30 20 19 37.5 to 750 37 116 26 170 96 Bore size (mm) N S U V T P J MM GR GE GF K L Q RR H VA W Z ZZ 32 27 154 13 6.5 34 1/8 10.5 M6

grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Condenser Bracket for HRS024

with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Comm D-Sub for HRS024

, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024

1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024

, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024