Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside actuators will become demagnetized. 3.
Q = T x L x x C 860 Q = T x L x x C 60 x 1000 6.0 x 1.2 x 1.80 x 103 x 0.23 860 = 6.0 x 20 x 1.80 x 103 x 0.96 x 103 = = 3.5 kW 60 x 1000 = 3456W = 3.5 kW Cooling capacity = Considering a safety factor of 20%, 3.5 x 1.2 = 4.2 kW Cooling capacity = Considering a safety factor of 20%, 3.5 x 1.2 = 4.2 kW Thermo-chiller T2: Return temperature Customers machine L T =T2 T1 T1: Outlet temperature
heat C: 4.2 x 103 J/(kgK) Q = T x L x x C 60 x 1000 T2: Return temperature Customers machine L 0.8 x 3 x 1 x 103 x 4.2 x 103 = T =T2 T1 HEC 60 x 1000 H = 167W L Cooling capacity = Considering a safety factor of 20%, 167W x 1.2 = T1: Outlet temperature 200W Example 3 When cooling the object below a certain temperature in certain period of time.
These items are included when ordered using the part number for an actuator set. [Options] Controller communication cable(Part No: JXC-W2A-C) USB cable (Part No: LEC-W2-U) Teaching box (Part No: LEC-T1-3G) When connecting the teaching box to the JXC9H controller, the P5062-5 cable is required.
pins flat cable) Connector block assembly (For 10 pins flat cable) Connector block assembly (For 2 to 8 stations (T, T1) terminal block) -1A: +COM -1NA: COM SX3000-64-1A 1NA SX5000-64-1A 1NA t-1 SX3000-64-26 2A 2NA SX5000-64-26 2A 2NA t-2 Note) 24 VDC -2A: +COM. -2NA: COM. 2A 2NA SX3000-64-20 2A 2NA SX5000-64-20 t-3 2A 2NA SX3000-64-10 2A 2NA SX5000-64-10 t-4 t-5 SX5000-64-3A SX3000-64-3A
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80, 100 R 1/2 AS121F-U10/
Do not expose the actuator motor to a magnetic field with a magnetic flux density of 1 mT or more. (1) When installing an air cylinder with an auto switch (ex. CDQ2 series) by side, maintain 40 mm minimum space around the motor.
Silent interval is indicated by T1-T2-T3-T4. Table 3.8-2 RTU mode message frame a)Start b)Slave Address c)Function d)Data e) Checksum (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (non-communication time).
A I-G04 I-G05 Y-G04 Y-G05 M14 x 1.5 42 56 14 18 22 28 30 40 12 16 14 20 42 56 16 20 22 28 M14 x 1.5 12 16 14 20 36 41.6 10 +0.058 0 18 IY-G04 IY-G05 30 40 +0.5 +0.3 M18 x 1.5 M18 x 1.5 44 50.6 14 +0.070 0 22 +0.5 +0.3 Knuckle pin and retaining ring are included.
This allows reading and monitoring the contact signal from an external switch. When inputting an external switch signal to the contact input, select External Switch (external switch signal) for the type of contact input signal. (Refer to 2.3.1 Setting of contact input signal type and form) If an input from an external switch is detected, it can be generated as an alarm.
Silent interval is indicated by T1-T2-T3-T4. Table 3-6 RTU mode message frame a) Start b) Device Address c) Function d) Data e) Checksum (CRC) f) End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (non-communication time).
Bore size (mm) 32, 40 50, 63 80 100 B D E F M T1 T2 Part no. CNG YA-03 YA-05 YA-08 YA-10 18 6.8 16 6 42 6.5 10 YA 03 20 9 20 8 50 6.5 12 MNB Applicable air cylinder bore 26 11 25 10 62 8.5 16 31 14 30 12 76 10.5 18 CNA 03 05 08 10 32, 40 50, 63 80 100 Bore size (mm) 32, 40 50, 63 80 100 Mounting bracket U V W Mass (g) Part no.
Nil Rod end female thread (Standard) Bore size M Rod end male thread 20 25 32 40 50 63 80 100 20 mm Cylinder stroke (mm) Refer to Standard Stroke on page 775. 25 mm 32 mm Thread type 40 mm Built-in Magnet Cylinder Model 20, 25 50 mm M thread Nil If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.
20 20 20 7.5 15 17.5 19.5 26.5 P.C.D 58.7 P.C.D 92.1 C D XYD/In-line type G Fd C (K flange) J K H B S M 45 A Fn (KF flange) E K (mm) Model A 86.7 114 128 163 193 B 48 66 79 100 117 C 1 2 2 3 3 D 23.5 38 53 61 80 E 40 55 75 87 114 Fn 95 110 Fd 26 41 52 70 83 G 66 84 95 121 144 H J XYD-25 XYD-40 XYD-50 XYD-63 XYD-80 100.2 130 178 209 268 16 20 20 20 20 7.5 15 17.5 19.5 26.5 10 Stainless
) (CF flange) A B K S M J H G A (mm) Model A 123 170 183 217 256 B 48 66 79 100 117 C 1 2 2 3 3 D 40 55 75 87 114 Fn 95 110 Fd 70 114 Fc 26 41 52 70 83 G 41 63 68 72 98 H J K P.C.D L1 6 x 6.6 8 x 8.4 L2 XMD-25 XMD-40 XMD-50 XMD-63 XMD-80 50 65 70 88 90 16 20 20 20 20 7.5 15 17.5 19.5 26.5 P.C.D 58.7 P.C.D 92.1 C D XYD/In-line type XLA G Fd XL C XLQ (K flange) XM XY XM XY J K H B
Stroke 25 36.5 5 22.5 10 14 20 10 20 10 (All dimensions but A and CL are identical to those of the basic style.)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DMU (DM+U)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: MU (M+U)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: T (High-pressure Pump Mounted)