SMC Corporation of America
Elite Part Number Search
Search Results "HECR008-A5-EFP"

A5 IN3 A5 IN3 A6 DRIVE A6 DRIVE A7 SVON A7 SVON Internal resistance 10 [k] Internal resistance 10[k] A8 NC A8 NC A9 NC A9 NC Main circuit Main circuit Output signal power Output signal power supply supply A10 NC A10 NC 24 VDC 24 VDC DC2(+) B1 DC2(+) B1 DC2(-) B2 DC2(-) B2 BUSY B3 BUSY B3 B4 ALARM B4 ALARM B5 OUT0 B5 OUT0 B6 OUT1 B6 OUT1 Maximum Output current 10 mA Maximum Output current

Please wire referring to the following diagram * NPN type * PNP type A1 COM CN5 I/O signal power 24VDC A1 COM CN5 I/O signal power 24VDC A2 COM A2 COM A3 IN0 A3 IN0 A4 IN1 A4 IN1 A5 IN2 A5 IN2 A6 IN3 A6 IN3 A7 IN4 A7 IN4 A8 IN5 A8 IN5 A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON Load B1 OUT0 Load B1 OUT0 B2 OUT1 Load B2 OUT1 Load B3 OUT2 Load

BBA1: For D-A5/A6/F5/J5 types * Refer to the Web Catalog or Best Pneumatics Catalog for details on the BBA1. The above stainless steel screws are used when a cylinder is shipped with the D-F5BA auto switch.

Front matter 1 Vacuum Saving Valve Series ZP2V How to Order ZP2V 03 A5 Connection thread symbol for the pad Fixed orifice size Male thread connection Applicable fixed orifice size Fixed orifice size (mm) Symbol Thread size Symbol 0.5 0.3 0.7 1.0 A5 A8 A01 AG1 AN1 03 05 07 10 0.3 M5 0.5 M8 No.0.8 0.7 R1/8 Male thread 1.0 G1/8 Pad side NPT1/8 Female thread connection Applicable fixed orifice

L1 A1 Adjusting bolt Static moment L2 A3 W MX Mp Mr My MTS W W W MY L1 A2 L3 A5 W L2 A4 CY Mey Note) No need to consider this load factor in the case of using perpendicularly in a vertical position.

(H120809) A5 Remote mounting accessories A6 Pressure gauges with connections G1/4. Material AISI 316. ID code Descpition RR01 C0217108 ND remote mount rotary sensor QNCOK05HDM A7 Pressure gauges with connections 1/4 NPT. Material AISI 316.

BBA1: For D-A5/ A6/ F5/ J5 types Refer to the Web Catalog or Best Pneumatics for details on the BBA1. The above stainless steel screws are used when a cylinder is shipped with the D-F5BA auto switch. When only one auto switch is shipped independently, the BBA1 is attached.

(Same side) 75+50(n2) n=2, 4, 6, 8 80+50(n2) n=2, 4, 6, 8 85+50(n2) n=2, 4, 6, 8 70 1 switch 75 80 85 1 switch, 2 switches (Different side, Same side) 80 95 105 110 60 D-A5 D-A6 60+55(n4)/2 n=4, 8, 12, 16 Other qty.

63 11.5 52 11.2 66 250 0 34 16 Strok 348 65 4.5 71 339 37 1/2 55 15 23 70 208 76 116 131 80 11.5 65 12.5 80 296 0 44 16 e 367 75 6 72 358 40 1/2 56.5 15 25 80 226 92 133 148 100 13.5 65 14 81 312 0 43 17 Note: Pre-wired Switches with 3/4 Pin Connectors available D I M E N S I O N S LONG STROKE F O O T T Y P E CLAL ACCESSORIES AUTO SWITCH BANDS Switch Model Applicable Bore Size Part No D-A5

Parallel I/O Connector: CN5 Wiring diagram LECP6Nll-l (NPN) LECP6Pll-l (PNP) Power supply 24 VDC for I/O signal CN5 Power supply 24 VDC for I/O signal CN5 A1 COM+ COM+ A1 COM COM A2 A2 A3 A3 IN0 IN0 A4 A4 IN1 IN1 A5 A5 IN2 IN2 A6 A6 IN3 IN3 A7 A7 IN4 IN4 A8 A8 IN5 IN5 A9 A9 SETUP SETUP A10 A10 HOLD HOLD A11 A11 DRIVE DRIVE A12 A12 RESET RESET A13 A13 SVON SVON Load Load B1 B1 OUT0 OUT0 B2

L1 L2+A5 L3 2 1 W V 2 E= ( ) 2 9.8 1000 Collision speed V=1.4 Va *) Corrected coeficient 1 420 E= 1( ) =0.088 2 1000 V=1.4 X 300=420 Calculate kinetic energy E (J) of work. Calculate allwable kinetic energy Ea (J). Check that kinetic energy of work does not exceed allowable kinetic energy.

.)/ NZX1OO-Kl&-E S9rcar ',,/Zn-Sl teo a5 standard) Air Eupply pressure port Applicable valve: NVJ300 (N.O.) / NZX1BOO -KSO -EO Applicable valve: Air oprated / NZX1@@-KeEe + l ilols ) l* Dimnsions I For n|ounting B.ackst A r* }lDinEnoions:With Spac.1 36 | *o $enie For Ejector System Use / Eiectot + Valve + Adsorption Confirmation Switch (ZSPI) (Dimensions in millimeters) Mofile Applicable

New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer

Pad Type _sfr A5 M5 x 0.8 o o A6 M 6 x 1 o o a a A 8 ' M 8 x 1 a o B4 M4 x 0.7 a B5 M5 x 0.8 o a a r 8 6 : , -Es'i M 6 x l a a o MBx 1.25 o o ' 5/3r' and 5/ i 6' lu be may be subslituted for 4mn and Bmm respectivty (Check teakage) 99 llonhontal IyF Uacuum Intn Willr Buflen lilitfi 0ne-T0uclr Tule ]ittin Specifications M8x1l\4alethread Mloxl Male thread Mloxl Male thread Ml4xl Male thread

CS1 Applicable Auto Switches Style Auto switch model Electrical entry (function) Grommet D-A5/A6 Reed switch Grommet (2 colour indication) D-A59W Grommet D-F5/J5 Grommet (2 colour indication) D-F5W/J59W Solid state switch Grommet (2 colour, Water resistant) D-F5BA Grommet (2 colour, diagnosis output) D-F5F Grommet (Timer) D-F5NT Accessories Basic Foot Front flange Rear flange Single rear

Parallel I/O Connector: CN5 M NPN output circuit MPNP output circuit COM COM A1 A1 24 VDC power supply for the input signals 24 VDC power supply for the input signals IN0 IN0 A2 A2 IN1 IN1 A3 A3 IN2 IN2 A4 A4 IN3 IN3 A5 A5 The power supply can be either polarity. The power supply can be either polarity.

LECP6Pll-l (PNP) Wiring diagram LECP6Nll-l (NPN) Power supply 24 VDC for I/O signal CN5 Power supply 24 VDC for I/O signal CN5 A1 COM+ COM+ A1 COM COM A2 A2 A3 A3 IN0 IN0 A4 A4 IN1 IN1 A5 A5 IN2 IN2 A6 A6 IN3 IN3 A7 A7 IN4 IN4 A8 A8 IN5 IN5 A9 A9 SETUP SETUP A10 A10 HOLD HOLD A11 A11 DRIVE DRIVE A12 A12 RESET RESET A13 A13 SVON SVON Load Load B1 B1 OUT0 OUT0 B2 B2 OUT1 OUT1 B3 B3 OUT2 OUT2

LECA6 LECP6 LEC-G LECP1 LECPA Parallel I/O Connector: CN5 Wiring diagram LEC6N(NPN) LEC6P(PNP) Power supply 24 VDC for I/O signal CN5 Power supply 24 VDC for I/O signal CN5 A1 A1 COM+ COM+ COM COM A2 A2 A3 A3 IN0 IN0 A4 A4 IN1 IN1 A5 A5 IN2 IN2 A6 A6 IN3 IN3 A7 A7 IN4 IN4 A8 A8 IN5 IN5 A9 A9 SETUP SETUP A10 A10 HOLD HOLD A11 A11 DRIVE DRIVE A12 A12 RESET RESET A13 A13 SVON SVON Load Load

Wiring diagram LECP6N(NPN) LECP6P(PNP) Power supply 24 VDC for I/O signal CN5 Power supply 24 VDC for I/O signal CN5 A1 A1 COM+ COM+ COM COM A2 A2 A3 A3 IN0 IN0 A4 A4 IN1 IN1 A5 A5 IN2 IN2 A6 A6 IN3 IN3 A7 A7 IN4 IN4 A8 A8 IN5 IN5 A9 A9 SETUP SETUP A10 A10 HOLD HOLD A11 A11 DRIVE DRIVE A12 A12 RESET RESET A13 A13 SVON SVON Load Load B1 B1 OUT0 OUT0 Load Load B2 B2 OUT1 OUT1 Load Load B3 B3

Step Motor (Servo/24 VDC) Wiring diagram LECP6N(NPN) LECP6P(PNP) Power supply 24 VDC for I/O signal CN5 Power supply 24 VDC for I/O signal CN5 A1 A1 COM+ COM+ COM COM A2 A2 A3 A3 IN0 IN0 A4 A4 IN1 IN1 A5 A5 IN2 IN2 A6 A6 IN3 IN3 A7 A7 IN4 IN4 A8 A8 IN5 IN5 A9 A9 SETUP SETUP A10 A10 HOLD HOLD A11 A11 DRIVE DRIVE A12 A12 RESET RESET A13 A13 SVON SVON Load Load B1 B1 OUT0 OUT0 Load Load B2 B2