Product Outline . 7 2.1 Features . 7 2.2 How to Order. 8 2.3 Product configuration . 9 3.
Dimensions with bracket Part number K F G H Q R S T U V W AMS20B-#C 85 71.2 103.2 76.2 35 7 14 54.5 6 47 42.5 AMS30B-#C 85 85.2 104.2 100.7 35 7 14 54.5 6 47 42.5 AMS40B-#C 85 103.2 105.2 122.2 40 9 18 65 7 55 50 AMS60B-#C 100 124.2 126.2 157.2 50 11 20 80 8 70 60 -139No.PF-OMA1007-B AMS20/30/40/60B-#00C Part number A F AMS20B-#00C 247.4 69.6 AMS30B-#00C 285.9 83.1 AMS40B-#00C 325.4 100.6
Intermediate strokes For manufacture of strokes other than the standard strokes above, add "-X2" at the end of the part number.
Intermediate strokes For manufacture of strokes other than the standard strokes above, add "-X2" at the end of the part number.
CE*OMI0064-C CEU5 1 . 1 2 . 4 2-1 . 4 2-2 . 4 3 . 5 4 . 7 5 . 9 6 . 10 6-1 . 10 6-2 . 10 6-3 . 11 6-4 . 11 6-5 RS-232C . 11 6-6 . 12 7 . 13 7-1 . 13 7-1-1 . 13 7-1-2 . 13 7-1-3 . 14 7-1-4 . 15 7-2 . 16 7-3 . 20 7-3-1 . 20 7-3-2 . 20 7-3-3 . 20 7-3-4 No. . 20 7-3-5 . 21 7-3-6 . 22 7-3-7 . 23 7-4 (E2ROM) . 25 8 RS-232C . 26 8-1 . 26 8-2 . 26 9 BCD .
Table. 7-3 Digital input allocation and the process data Connector position Connector designation X0 X1 X2 X3 X4 X5 X6 X7 Pin 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 Input Pin 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 -41No.EX##-OMU0020-A 7.5.
(3-3) LECPLECA .59 (3-3-1) LECPLECA . 61 (3-3-2) LECPLECA . 62 (3-3-3) LECPLECA . 64 2 - (4) .68 (4-1) .68 (4-2) .68 (4-3) .69 (4-3-1) . 69 (5) .70 (5-1) .70 (5-2) .70 (5-3) .70 (5-3-1) . 70 (5-3-2) . 72 (5-3-3) . 73 (5-3-4) . 76 (6) .79 (6-1) .79 (6-2) .79 (6-3) .79 (6-3-1) . 79 (6-3-2) . 80 (6-3-3) . 82 (6-3-4) . 83 (6-3-5) . 83 (7) .84 (7-1) .84 (7-2) .84 (7-3) .85 (7-3-1) . 85 (7-3-
IDF100150F 6-6 Consumable parts and regular maintenance parts 6 9 IDX-OM-M050 Air Dryer 7 Service Record Service Record 7-1 Service Record It is recommended to keep a maintenance/service record. Parts No.
Display of condition 0 1 0 1 0 1 2 3 2 3 Controller 4 5 4 5 6 7 6 7 2 3 4 5 6 7 Enlarged view Display Content Protective equipment Condition On Normal 0 Phase reverse relay Automatic reset type Off The power supply is incorrectly connected or interrupted. On Normal 1 Compressor thermal relay Manual reset type Off Over current is flowing to the compressor.
2.2 IDX-OM-U022 2. 2.3 ()2 1. 2. 3. 4. 4 4.2 IDFA100F150F 2 8 2.3 IDX-OM-U022 3. / / 3.1 INOUT R 3.2 1) ONON 2) 3) IN 4) OUT 5) 5 6) 7) IDFA100F150F 3 1 3.1 IDX-OM-U022 3. / ONOFF 0.05MPa 3.3 OFF OFF 3.4 3 3 5 3.5 OFF 3.6 24H IDFA100F150F 3 2 3.3 IDX-OM-U022 3. / 3.7 0 1 1 0 1 0 3 2 3 2 5 4 5 4 7 6 7 6 2 3 4 5 6 7 0 1 2 3 4 5 OFF OFF5.2 3 3 IDFA100F150F
A C B ) M-01AN-4 M-01AN-6 M-01AU-4 M-01AU-6 5 7 5 7 16 18 16 18 2.1 4.0 2.1 4.0 1.8 2.5 1.8 2.5 Nylon tube Soft tube Hose nipple: M-01H-4, -6 Effective orifice(mm2 Weight (g) ) Part No.
Pressure Gauge: G46 (ø42 Outside Diameter, Back Side Thread), Display Pressure: 4 (0.4MPa), Connection Thread: 01 (R 1/8), Attachment: None, Option: X2 (Nickel Plated)
Pressure Gauge: G46 (ø42 Outside Diameter, Back Side Thread), Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8), Attachment: None, Option: X2 (Nickel Plated)
Pressure Gauge: G46 (ø42 Outside Diameter, Back Side Thread), Display Pressure: 2 (0.2MPa), Connection Thread: 01 (R 1/8), Attachment: C2 (Clear Cover Removable, Wrench Tighten), Option: X2 (Nickel Plated)
Pressure Gauge: GA46 (ø42 Outside Diameter, Vertical Side Thread), Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8), Attachment: None, Option: X2 (Nickel Plated)
Display Pressure: 4 (0.4MPa), Connection Thread: 01 (R 1/8), Option: X2 (Stud Parts Nickel Plated)
Display Pressure: 2 (0.2MPa), Connection Thread: 01 (R 1/8), Option: X2 (Stud Parts Nickel Plated)
Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8), Option: X2 (Stud Parts Nickel Plated)