BBA3: For D-B5/B6/G5/K5 D-G5BAL auto switch is set on the cylinder with the stainless steel screws above when shipped. When an auto switch is shipped independently, BBA3 screws are attached. Stainless Steel Mounting Screw Set Part no. Description Part Size Qty. Applicable auto switch mounting bracket part no.

Typ. 32 1/16 B2 1/2 1/16 B2 1/16 B4 1/16 B6 1/16 B3 1/16 B1 1/16 B5 Elbows: 1/16 NPT Male to Tube 1 2 15 32 3 8 3 8 17 32 3 8 19 32 17 32 19 32 17 32 Typ. Typ. 21 64 33 1/16 LB2 1/2 1/16 LB2 1/16 LB4 1/16 LB3 1/16 LB1 1/16 LB5 LTees: 1/16 NPT Male to Tube 45 Elbows NEW Note: also available with #1, #2, & #4 barbs Note: Also available in Reducing L-Tee combinations.

no.) 20 A1 B1 Produced upon receipt of order (Robotic cable only) (13.5) A6 B6 1 2 Connector D (14.7) 15 16 Connector A Cable type (30.7) L (11) (10) Robotic cable (Flexible cable) Standard cable Nil Connector C terminal no.

D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30

MODE B6 MODE Load Load B7 BUSY B7 BUSY Load Load B8 AREA B8 AREA Load Load B9 SETON B9 SETON Load Load B10 INP B10 INP Load Load B11 SVRE Load B11 SVRE Load Load B12 *ESTOP Load B12 *ESTOP *ALARM B13 Load *ALARM B13 Load 14 No.JXC-OMW1019-A 5.

A5 IN3 A5 IN3 A6 DRIVE A6 DRIVE A7 SVON A7 SVON Internal resistance 10 [k] Internal resistance 10[k] A8 NC A8 NC A9 NC A9 NC Main circuit Main circuit Output signal power Output signal power supply supply A10 NC A10 NC 24 VDC 24 VDC DC2(+) B1 DC2(+) B1 DC2(-) B2 DC2(-) B2 BUSY B3 BUSY B3 B4 ALARM B4 ALARM B5 OUT0 B5 OUT0 B6 OUT1 B6 OUT1 Maximum Output current Maximum Output current B7 NC

OUT1<B6> DC2(-) 10k (3) Pulse train signal input circuit The pulse signal input can be selected from the open collector input type and differential input type.

Stainless steel mounting screw kit: BBA3 for D-B5, D-B6, D-G5, and D-K5 Stainless steel mounting screw kit: BBA4 for D-C7, D-C8, and D-H7 When the type D-H7BAL switch is shipped already mounted on a cylinder, the above stainless steel screws are used.

Elbow fitting assembly (Downward) B4: 4 elbow fitting assembly B6: 6 elbow fitting assembly 5 (EA) 1 (P) 3 (EB) 4 position dual 3 port valve: N.C./N.C. A 4 Back pressure check valve (A) 4 (B) 2 Nil K None A 2 B SOL.b SOL.a 3 (R) 5 (R) Built-in The built-in back pressure check valve type has an effective area approximately 20% smaller.

Elbow fitting assembly (Downward) B4: 4 elbow fitting assembly B6: 6 elbow fitting assembly 5 (EA) 1 (P) 3 (EB) 4 position dual 3 port valve: N.C./N.C. A 4 Back pressure check valve (A) 4 (B) 2 Nil K None A 2 B SOL.b SOL.a 3 (R) 5 (R) Built-in The built-in back pressure check valve type has an effective area approximately 20% smaller.

B6 OUT5 B7 BUSY This terminal is ON during the movement of the electric actuator. (During the positioning operation, etc.). Caution During the pushing operation without movement (no movement but the electric actuator generating the pushing force), BUSY is OFF. BUSY signal stays on for 50ms or longer after operation starts.

Hs 8.5 8.5 Auto switch Auto switch 16 16 A 36.7 B A 38.2 B D-B5, D-B6, D-B59W D-A3, D-G3, D-K3 Approx. Hs Auto switch 36 Approx. Hs 12 Auto switch 24.5 34 SMC AUTO SWITCH SMC AUTO SWITCH A 49 A 33 6.5 B D-G5, D-K5, D-G5W, D-G5BA, D-K9W, D-G59F, D-G5NT D-A44 12 Auto switch Approx. Hs 36 Approx.

B 2 2(B) 4(A) B Elbow fitting assembly (Downward) B4: 4 elbow fitting assembly B6: 6 elbow fitting assembly 1(P) 5(EA) 3(EB) A 4 4 position dual 3 port valve: N.C./N.O.

BBA3: For D-B5/B6/G5/K5 BBA4: For D-C7/C8/H7 The above screw made of stainless steel is used for D-H7BAL switch when cylinder mounting is shipped. BBA4 is attached when switch is shipped. 4.9-7 Series REC How to Select Model Selection Procedures Provisional selection accordling to absorbed energy Please refer to graph q.

Red 4 Lock (+) B-1 Black 5 Lock (-) A-1 Brown 1 Sensor (+) B-3 Blue 2 Sensor (-) A-3 Actuator side Controller side 2 1 (5.5) (6.3) (1) (14) (18) B1 A1 6 (2) 5 (17.7) (14.2) A6 B6 (3) 2 (10.2) 1 B1 A1 B3 A3 15 16 -56No.

B A-6 Black 8 3 Actuator side Controller side (14.2) (2) 2 1 (5.5) (14) (1) B1 A1 5 6 (17.7) (3) 2 1 A6 B6 (18) (6.3) 16 15 L (11) (30.7) -59No.

Red 4 Lock (+) B-1 Black 5 Lock (-) A-1 Brown 1 Sensor (+) B-3 Blue 2 Sensor (-) A-3 Actuator side Controller side 2 1 (5.5) (6.3) (1) (2) (14) (18) B1 A1 6 5 (17.7) (14.2) A6 B6 2 1 (10.2) B1 A1 B3 A3 (3) (4) (5.7) 15 16 L (11) (30.7) -60No.

Actuator side Controller side (14.2) (2) 1 2 (5.5) (14) (1) B1 A1 5 6 (17.7) (3) 2 1 A6 B6 (18) (6.3) 15 16 L (11) (30.7) 12 - [3] Actuator cable for actuator with lock (for sensor and lock) [5m or less] LE CP B (1) (2) Signal name Terminal No. Cable color Terminal No.

15 16 (11) 30.7 L 15.2 [820m] 1 2 LE CP 2 A B-1 L 1 A A-1 6 B B-2 8 8m * 5 B A-2 3 COM-A/COM B-3 A 10m * 4 COM-B/ A-3 B 15m * 3 Shield C 20m * 12 Vcc B-4 13 GND A-4 * 7 A B-5 6 A A-5 * 9 B B-6 8 B A-6 3 (14.2) (2) 2 1 5.5 (18) (14) A1 B1 1 6 5 17.7 (3) 2 1 A6 B6 6.3 16 15 30.7 L (11) 59 - 15.3 [5m ] LE-CP--B(1) 2 A B-1 2 L A A-1 1 B B-2 6 B A-2 5 COM-A/COM B-3 3 COM-B

15 16 L (11) (30.7) 14.2 [820m] LE-CP(1) (2) * * A B-1 2 (L) A A-1 1 B B-2 6 8 8m * B A-2 5 COM-A/COM B-3 3 A 10m * COM-B/ A-3 4 B 15m * (3) Shield C 20m * Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 (14.2) (2) 1 2 (5.5) (14) (1) B1 A1 5 6 (17.7) (3) 2 1 (18) A6 B6 (6.3) 15 16 (11) (30.7) -58- 14.3 ()[5m ] (1) (2) LE CP B A B-1 2 A A-1 1 (L) B (B-2) 6 B