At the setting of STA 20, STB 5000 and STC 200, the actual arc part times are as follows. (Example) Limited to 100[ms] since During acceleration: 100[ms] 20 20 100[ms] 200[ms]. 200[ms] as set since During deceleration: 200[ms] 20 5000 400[ms] 200[ms].
Note 2) When the valve is a standard (dustprotected) specification, it is not compatible with 200 or 220 VAC.
[mm] Ionizer front back direction [mm] 150 100 50 0 50 100 150 150 100 50 0 50 100 150 250 200 150 100 50 0 50 100 150 200 250 0 0 50 50 100 100 1 s 0.5 s 150 150 0.5 s 200 200 2 s 1 s 2 s 250 250 5 s 5 s 300 300 3) With energy saving type de-ionizing cartridge, Supply pressure: 0.3 MPa Installation distance in height from ionizer to workpiece (Charged object location) [mm] Installation
Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 RE A B Auto switch model Applicable load PLC Relay, PLC REC Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA CX Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 CL Auto switch model Applicable load PLC Relay, PLC CL1 Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MLGC Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 CJ1 Auto switch model Applicable load PLC Relay, PLC CJP Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA CJ2 Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (
Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.
Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.
Size: 25, Motor Mounting Position: In-line (sizes 25, 32, 40, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 25: 12; Size 32: 16; Size 40: 20), Stroke: 400mm, Motor Option: without Option, Grease Application: with, Controller Position: B (Integrated Controller), Parallel Input: 5 (NPN)
Size: 25, Motor Mounting Position: In-line (sizes 25, 32, 40, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 25: 12; Size 32: 16; Size 40: 20), Stroke: 150mm, Motor Option: without Option, Grease Application: with, Controller Position: B (Integrated Controller), Parallel Input: 5 (NPN)
Size: 25, Motor Mounting Position: In-line (sizes 25, 32, 40, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 25: 12; Size 32: 16; Size 40: 20), Stroke: 250mm, Motor Option: without Option, Grease Application: with, Controller Position: B (Integrated Controller), Parallel Input: 5 (NPN)
Size: 25, Motor Mounting Position: In-line, Motor Type: Battery-less Absolute, Step Motor 24 VDC, Lead, mm: Size 25: 12; Size 32: 16; Size 40: 20, Stroke: 400mm, Motor Option: without Option, Grease Application: with, Controller Position: Integrated Controller, Parallel Input: NPN
Size: 25, Motor Mounting Position: In-line, Motor Type: Battery-less Absolute, Step Motor 24 VDC, Lead, mm: Size 25: 12; Size 32: 16; Size 40: 20, Stroke: 150mm, Motor Option: without Option, Grease Application: with, Controller Position: Integrated Controller, Parallel Input: NPN
Setup communication cable part number (with A-miniB type USB cable): JX-CT-E PC 120.3 120.3 mm mm Electric actuator 200 200 mm/s mm/s Setup communication cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 USB cable A-miniB type PC is prepared by the user. ..
Setup communication cable part number (with A-miniB type USB cable): JX-CT-E PC 120.3 120.3 mm mm Electric actuator Setup communication cable 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 USB cable A-miniB type PC is prepared by the user. ..
Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models. 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Connector 12 V Yes 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 MX Auto switch model Applicable load PLC Relay, PLC MTS Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MY Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (to
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 MX Auto switch model Applicable load PLC Relay, PLC MTS Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MY Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (to
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 MX Auto switch model Applicable load PLC Relay, PLC MTS Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MY Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less (to