M) 5 (Z) Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire Reed switch Solid state switch 5 V, 12 V 12 V IC circuit Relay, PLC Yes Yes No 24 V Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12 V 3-wire (NPN equivalent) A96V A96 5 V IC circuit DGrommet A93V A90V A93

IC circuit A96V A96 5 V Yes 24 V Grommet A93V A90V A93 A90 100 V Relay, PLC 2-wire 12 V IC circuit No 100 V or less Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction.

A Cable length Standard Stroke M L Z 1 m 3 m 5 m Nominal size Standard stroke (mm) Made to Order Long stroke (-XB11) Stroke range (mm) The remote control type can be selected by adding the above symbols. 16, 25 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 601 to 1000 Strokes are manufacturable in increments of 1 mm, up to 1000 strokes.

Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.

MK-A012 MK-A016 Bore size (mm) 12 16 20 25 32 40 50 63 12 70 87 16 100 123 20 250 290 25 280 320 32 500 525 40 595 640 50 1100 1350 63 1520 1805 Clamp bolt, Hexagon socket head cap screw, Hexagon nut, Spring washer MK-A020 MK-A032 Additional Weight MK-A050 Unit: g 63 17 46 25 350 531 50 7 46 13 350 345 32 7 21 5 200 166 40 6 21 7 200 198 25 7 10 3 100 153 12 13 16 32 20 6 10 2 100

, 400 450, 500 15 1000 750 25 32 200, 250, 300, 350, 400, 450 500, 600, 700, 800 2000 1500 Note) Intermediate strokes can be arranged in 1mm increments.

The detection position can be changed under the conditions described in step e. : 2. 3. 4. 5. 350 Rotary Cylinder With Auto Switch Series MRQ Auto Switch Mounting Dimensions Reed switch D-A7/A80 D-A7H D-A73C/A80C CRB2 (In parentheses) are the dimensions of A72.

. + = 4 . 1 = a V V 2 V m M E k 2 Ek: Kinetic energy (J) M : Mass of object being transported (kg) m : Mass of moving parts of cylinder (kg) V: Maximum speed (m/s) Va: Average speed (m/s) Mass of moving parts of cylinder (kg) Bore size Standard stroke (mm) (mm) model 20 25 30 40 50 75 100 125 150 175 200 250 300 350 MLGPM20 0.40 0.42 0.45 0.47 0.59 0.65 0.71 0.77 0.83 0.89 1.08 1.20 1.31

Indicator light Lead wire length (m) Applicable load 0.5 (Nil) 3 (L) 5 (Z) Auto switch model Special function Type Load voltage AC DC Wiring (Output) Electrical entry Pre-wire connector In-line Perpendicular Reed switch 3-wire (NPN equivalent) IC circuit A96 A96V 5 V Grommet Yes 2-wire 24 V A93 12 V 100 V Relay, PLC A93V 3-wire (NPN) 3-wire (PNP) M9N M9NV IC circuit 5 V, 12 V M9PV

Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with a symbol are produced upon receipt of order.

Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.

Standard stroke (mm) Bore size (mm) 25, 32, 40 50, 100, 150, 200, 250, 300 350, 400, 450, 500, 550, 600 1500 Stroke adjustment unit symbol For stroke adjustment unit, refer to page 1209. Intermediate fixing spacer is not available for end lock mounting side. Strokes are manufacturable in 1 mm increments, up to the maximum stroke.

A93 3m . L (Ex.) A93L 5m . Z (Ex.) F9NWZ Solid state auto switches marked with a "" are produced upon receipt of order.

Indicator light Lead wire length (m) Applicable load 0.5 (Nil) 3 (L) 5 (Z) Auto switch model Special function Type Load voltage AC DC Wiring (Output) Electrical entry Pre-wire connector In-line Perpendicular Reed switch 3-wire (NPN equivalent) IC circuit A96 A96V 5 V Grommet Yes 2-wire 24 V A93 12 V 100 V Relay, PLC A93V 3-wire (NPN) 3-wire (PNP) M9N M9NV IC circuit 5 V, 12 V M9PV

Load A Displacement MSQ1A MSQ10 MSQB10 (Basic type) CRB2 MSQB1A (Basic type) 100 CRBU2 Displacement m Displacement m 400 80 MSQA1A (High precision type) CRB1 60 350 MSU 40 10 20 30 40 MSQA10 (High precision type) 20 CRJ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Indicator light Lead wire length (m) Applicable load 0.5 (Nil) 3 (L) 5 (Z) Auto switch model Special function Type Load voltage AC DC Wiring (Output) Electrical entry Pre-wire connector In-line Perpendicular Reed switch 3-wire (NPN equivalent) IC circuit A96 A96V 5 V Grommet Yes 2-wire 24 V A93 12 V 100 V Relay, PLC A93V 3-wire (NPN) 3-wire (PNP) M9N M9NV IC circuit 5 V, 12 V M9PV

IC circuit 5 V, 12 V 3-wire (PNP) Relay, PLC 2-wire 12 V Grommet 5 V, 12 V 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 12 V 2-wire Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) A93L 5 mZ (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-10-22 for details.

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 350mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal

Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 350mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 3 pcs.