Features Electrical entry D-F7NV, F7PV, F7BV Grommet (perpendicular) Diagnostic indication (2-color indicator) D-F7NWV, F7BWV Water resistant (2-color indicator) D-F7BAV Solid state D-F79, F7P, J79 Diagnostic indication (2-color indicator) D-F79W, F7PW, J79W Grommet (in-line) Water resistant (2-color indicator) D-F7BA With timer D-F7NT D-A73 Grommet (perpendicular) Without indicator light
voltage Auto switch model Indicator light Special function Type Electrical entry Pre-wire connector Wiring (Output) Applicable load Rail mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet 200 V 100 V 12 V 12 V C73 C73C H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7NF A72H A73H F79
voltage Auto switch model Indicator light Special function Type Electrical entry Pre-wire connector Wiring (Output) Applicable load Rail mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet 200 V 100 V 12 V 12 V C73 C73C H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7NF A72H A73H F79
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 3.62468 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 3.94001 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 4.28158 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 4.40924 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 4.62970 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 3.04972 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 4.18878 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 4.27145 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 3.99514 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 3.99514 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 350mm, Adjuster: B (Shock Absorbers (2 pcs))
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 150mm, Adjuster: B (Shock Absorbers (2 pcs))
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 750mm, Adjuster: B (Shock Absorbers (2 pcs))
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 450mm, Adjuster: B (Shock Absorbers (2 pcs))
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 200mm, Adjuster: B (Shock Absorbers (2 pcs))