Lead wire length symbols: 0.5 m Nil (Example) M9NW Solid state auto switches marked with v are produced upon receipt of order. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics.
Basic, Foot, Rod flange, Head flange, Clevis (Used for changing the port location by 90) Mounting Male rod end Female rod end 0.2 J 0.29 J 0.46 J 0.84 J 1.4 J 2.38 J 4.13 J 6.93 J Allowable kinetic energy Symbol Specification 0.11 J 0.18 J 0.29 J 0.52 J 0.91 J 1.54 J 2.71 J 4.54 J -XA Change of rod end shape Operate the cylinder within the allowable kinetic energy.
W L Mounting hole W Intermediate support mounting hole L L Distance between Load and Supports Mounting hole 140 130 25 120 CY3B CY3R 110 100 CY1S 90 4. When a 25 mm adjustment bolt is selected, the mounting holes will be hidden behind it. Adjust the adjustment bolt after the cylinder is installed. According to 2.
The moving direction of the finger can be changed by 90 degree depending on the mounting position. After determining the mounting position, correct the angle of the moving direction of the finger on the duAro if necessary. (44.
(Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.
D-A9V D-M9WV D-Y7PV D-P3DWA D-P3DW D-P4DW D-Y59/Y7P D-M9AV D-Y7WV D-Y7W D-Y7BA Bore size (mm) Hs Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 20 18.5 22 24.5 20 25 20.5 24 26 21.5 32 30 32 23 26.5 29 24.5 35 33 41.5 40 27 30.5 33 28.5 39 37 44.5 50 32.5 36 38.5 34 44.5 42.5 50 63 39.5 43 45.5 41 51.5 49.5 57 80 40 43 71.5 45 74 41 70 49.5 84 48 78.5 61 84.5 100 50 53 83 55 85.5 51 81.5 60 95 58 90
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ DNote 1) When using the 2-color indicator type, please make the setting so that the indicator is lit in red to ensure the detection at the proper position of the air gripper.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 26 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785 of Best Pneumatics No. 3.
Lead wire length symbols: 0.5 m Nil 1 m M 3 m L 5 m Z (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 419 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ marked solid state auto switches are produced upon receipt of order. Refer to page 652 for details, because there are other auto switches available than above models.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ There are other applicable auto switches other than the listed above. For details, refer to page 1197. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649.
x 1 (Width across flats 3) M8 x 1 (Width across flats 4) MXY8 30 70 10 40 29 M4 x 0.7 25 20.9 3.5 25 4 14 5 2.5 MXY12 40 M5 x 0.8 8.5 86 15 52 31 18 36 30.9 32 5 6 3 PH R RH RL T TB P PL PR Q QW TH W WD WE WR Z Model MXY6 4 2.9 5.1 13 7 9 11 60 12 3(depth 3) 3(depth 3) 2.5 30 5 88 25.5 20 MXY8 4 3.4 6.1 19 7 10 13 70 15 3(depth 3) 3(depth 3) 3 38 6.5 98 32 25 MXY12 5 4.5 7.8 29 7 13 18 90
Lead wire length symbols: 0.5 m Nil 1 m M 3 m L 5 m Z (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 167 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 351 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
Basic, Foot, Rod flange, Head flange, Clevis (Used for changing the port location by 90) Mounting Male rod end Female rod end 0.2 J 0.29 J 0.46 J 0.84 J 1.4 J 2.38 J 4.13 J 6.93 J Symbol Specification Allowable kinetic energy 0.11 J 0.18 J 0.29 J 0.52 J 0.91 J 1.54 J 2.71 J 4.54 J -XA Change of rod end shape Operate the cylinder within the allowable kinetic energy.
B Basic (Double-side bossed) L Axial foot F Rod ange G Head ange C Single clevis D Double clevis U Rod trunnion T Head trunnion E Integrated clevis V Integrated clevis (90) BZ Boss-cut/Basic FZ Boss-cut/Rod ange UZ Boss-cut/Rod trunnion * Air-hydro type: Rc only * No bracket is provided for the female rod end. * A knuckle joint pin is not provided with the single knuckle joint. * Rod end
(Figure 2) Then, rotate the lever by 90 to confirm that the indicator LED of the proximity switch (red, green) does not turn on. Fix the cylinder with screws included as accessories after confirming that there is no interference between the lever and the proximity switch.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. For D-P3DWA, 32 to 63 are available. DSince there are other applicable auto switches than listed, refer to page 400 for details.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) J79CN Since there are other applicable auto switches than listed, refer to page 18 for details. For details about auto switches with pre-wired connector, refer to page Best Pneumatics 2004 catalog.
M9NW M9PW M9BW M9NV M9PV M9BV M9NWV M9PWV M9BWV 3-wire (NPN) IC circuit Solid state switch 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet Yes 3-wire (NPN) IC circuit Diagnostic indication (2-color display) 5 V, 12 V 3-wire (PNP) 12 V 2-wire Lead wire length symbols: Auto switches marked with are made to order specification. 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM