Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to Best Pneumatics No. 2. Auto switches are shipped together, (but not assembled).
A96 A96V 5 V IC circuit Grommet Yes A93 A90 A93V A90V IC circuit 100 V Relay, PLC 2-wire 24 V 12 V No 100 V or less Lead wire length symbols: 0.5 m .Nil (Example) M9NW 1 m . M (Example) M9NWM 3 m . L (Example) M9NWL 5 m . Z (Example) M9NWZ Solid state auto switches marked with a symbol are produced upon receipt of order.
n 2 (" 2. 4. 6. 8 ..) (" = 4. 8. 12. ' 6 ..) (" =4. 8. ' 2. '6.. ) (" = 4. 8. ' 2. ' 6 .. ) With 2 pes tDrtterent slIriaces, 90 80 85 '0 Same surface), Wilh 1 pc. D-M90V D-M90WV 80 + 3O
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Note 1) Take note of hysteresis with 2-color indication type switches. Refer to page 438 for detailed auto switch specifications.
LAT LEJS40 LEJS63 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 LZ *4 Please consult with SMC for non-standard strokes as they are produced as special orders. LC3F2 * Specifications and dimensions for the 25A-series are the same as standard products.
Material of body and guide block is martensitic stainless steel. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Stroke adjuster 10 Three types (rubber stopper, metal stopper, shock absorber) are available. 20 With shock absorber 30 40 50 60 70 80 90 Auto switch attachable Highly flexible piping methods 100 Switch rail and magnet (Standard) Without switch rail and magnet
Lead wire length (m) Applicable load Pre-wired Load voltage Auto switch model Applicable bore (mm) Indicator light Wiring (Output) Special function Electrical entry Type AC 3 (L) 1 (M) 5 (Z) 0.5 (Nil) None (N) connector DC 20, 25 40, 50 32 M9N M9P M9B H7C M9NW M9PW M9BW H7BA H7NF 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) Grommet Reed switch Solid state switch 2-wire 12 V Connector Yes
Indicator light CE marking, RoHS Standard Oilproof Flexible Heavy-duty Lead Wire Specifications Auto switch model D-M9NW(V) D-M9PW(V) D-M9BW(V) Precautions Caution Sheath Outside diameter [mm] 2.6 3 cores (Brown/Blue/Black) 2 cores (Brown/Blue) Number of cores Insulator Fix the auto switch with the existing screw installed on the auto switch body.
Refer to pages 90 and 91 for the details. When actuator is used outside of operating limits, eccentric loads on guide will be in excess of this causing vibration on guide, inaccuracy, and shortened life. 2. If intermediate stops by external stopper is done, avoid ejection. If lurching occurs damage can result.
32 32 43 43 64 64 78 39 43 49 59 71 82 106 +0.058 0 +0.058 0 129 151 185 208 237 263 298 10 10 14 14 22 22 25 33 33 45 45 65 65 75 MB-B03 +0.070 0 MB-B05 +0.070 0 +0.084 0 +0.084 0 +0.084 0 MB-B08 MB-B12 B Rotation 90 Bore size (mm) A B A + B + 90 20 25 32, 40 50, 63 80 35 30 30 35 30 50 50 50 50 35 175 170 170 175 155 A MGJ MGP Clevis Pin MGQ 2 x d Dd9 d Note) Cotter pin Bore size (mm)
Weight (g) D-F79F Auto switch model 0.5 m (Nil) 13 3 m (L) Lead wire length 56 5 m (Z) 90 Diagnostic Output Operation The diagnostic output signal is output within the red display area (where indicator light is Red), and it is not output within the proper operating range (where indicator light is Green).
59 16 107 58 110 M14 x 1.5 15 65 19 Up to 1000 3 30 14 47 78 43 31 50 161 18 110 146 1/4 128 28 17 36 36 90 59 16 114 64 110 M14 x 1.5 15 75 19 Up to 1200 5 46 14 56 53 182 95 23 132 169 1/4 144 32 20 40 40 90 59 43 18.5 130 74 120 17 36 80 22 M16 x 1.5 +0.100 0 Up to 1200 118 30 16 5 63 60 204 106 36 167 195 3/8 162 40 23 50 45 115 70 48 17 18.5 149 86 135 20 41 90 26 M18 x 1.5 +0.100
55 75 80 90 75 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 80 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 90 + 35 (n 2) (n = 2, 4, 6, 8, ) Note 1) 20 + 35 (n 2) (n = 2, 3, 4, ) (Different surfaces) D-A44C n 75 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 80 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 90 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 55 + 50 (n 2) (n = 2, 3, 4, ) (Same surface) 1 10 75 80 90 2 (Different
, 100 80 25 20 15 100 10 30 35 40 45 50 60 70 75 80 90 40 35 30 25 20 15 100 10 45 50 60 70 75 80 90 Model CXS10 CXS15 CXSJ 30 40 50 97 92 87 82 102 107 112 117 122 132 142 147 95 90 85 80 75 70 65 100 105 115 125 130 55 45 25 35 45 99 94 89 109 114 119 124 129 139 149 154 104 159 169 179 95 90 85 80 75 70 105 110 120 130 135 100 140 150 160 CXS D-X Individual -X 567 Series CXS Dimensions
63 35 14 16 155 23 25 30 M14 x 1.5 Up to 1000 50 47 161 245 1/2 3/8 128 136 36 90 63 35 14 16 180 28 30 30 M14 x 1.5 Up to 1200 56 53 182 290 1/2 3/8 144 144 40 90 63 43 14 18.5 215 35 35 35 M16 x 1.5 (mm) Bore size (mm) K KA M MA MM N P Q R S T V VA H ZZ 125 140 160 15 31 27 M12 x 1.75 M30 x 1.5 35 1/2 85.5 25 303 87.5 20 23 110 440 15 31 27 M12 x 1.75 M30 x 1.5 35 1/2 93.5 25 343 95 20
As a rule, it can be turned about 90 past the point at which tightening can be felt. Switch mounting screw (M2.5 x 4 l) (included) 25 to 63 Mounting Bracket Part No.
L x 110 L x 65 L 75 90 110 65 MLGC -25D -25D x 80 L x 95 L x 115 L x 70 L 80 95 115 70 -30D -30D x 85 L x 100 L x 120 L x 75 L 85 100 120 75 10.5 CNG -35D -35D 7 12.5 17 x 90 L x 105 L x 125 L x 80 L 90 105 125 80 -40D -40D x 95 L x 110 L x 130 L x 85 L 95 110 130 85 MNB -45D -45D x 100 L x 115 L x 135 L x 90 L 100 115 135 90 -50D -50D x 105 L x 120 L x 140 L x 95 L 105 120 140 95 CNA -75D
(Resin, Carbon steel) Roller 590 RS2H Series The roller lever direction can be changed in 90 steps. To adapt the roller lever of the stopper to the work piece direction, the roller lever can be positioned in 4 different directions in 90 steps around the piston rod.
degree, it should be calculated to 2s/90 degree.