Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.12~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread
Stroke Variations Stroke [mm] Bore size [mm] Bearing type Made to Order 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 -XA: Change of guide rod end shape -XB6: Heat resistant cylinder (10 to 150C) -XB10: Intermediate stroke (Using exclusive body) -XB13: Low speed cylinder (5 to 50 mm/s) -XC6: Made of stainless steel -XC8: Adjustable stroke cylinder/ Adjustable extension type -XC22
stainless steel 20 to 100 Note 6) v v XC8 Adjustable stroke cylinder/Adjustable extension type XC9 Adjustable stroke cylinder/Adjustable retraction type v v XC10 Dual stroke cylinder/Double rod type v 20 to 63 XC11 Dual stroke cylinder/Single rod type v XC12 Tandem cylinder v v v Note 15) XC13 Auto switch rail mounting 20 to 100 v v v XC20 Head cover axial port 20 to 63 v v XC22
-XC6 Piston rod and rod end nut made of stainless steel -XC8 Adjustable stroke cylinder/Adjustable extension type Theoretical Output -XC9 Adjustable stroke cylinder/Adjustable extension type -XC22 Fluoro rubber seals OUT IN -XC35 With coil scraper (N) -XC69 With shock absorber Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) -XC79 Machining tapped
Part Number Description: FINGER ASSY/MHQ2-10D S C Product Line: A Product Line Description: ACTUATOR Family Code: 506 Family Description: MHQ/MHP GRIPPERS Class Code: E1 Part Code: 2 Reference Code: J This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
MH*-OMC0028 PRODUCT NAME Parallel Type Air Gripper MODEL / Series / Product Number MHL2-10D* MHL2-16D* MHL2-20D* MHL2-25D* MHL2-32D* MHL2-40D* Contents 1. Safety Instructions 2. Product Specifications 3. Operating method or operation 3-1. Operating environment 3-2. Air supply 3-3. Lubrication 3-4. Mounting 3-5. Finger attachment 3-6. Selection 3-7.
Double piston construction achieves compact design with strong gripping force. q r Mounting is possible from 4 directions. e w Model Bore size Gripping force (N) q w MHF2-8D MHZ2-10D 8 10 19 11 MHF2-12D MHZ2-20D 12 20 48 42 w e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 12-3-3 4 Series MHF2 Model Selection Model Selection Selection Procedure Confirm gripping force Confirm
*Through-hole mounting is not used when mounting the auto switch for the 90-MHZJ2-10D. *When using the perpendicular auto switch for 10, the fitting and auto switch could mutually interfere.
An auto switch for detecting the location can be mounted. 10D MHZ2-16D 20D 10DN MHZ2-16DN 20DN Tool stand Added to the standard tool adapter The height for setting a tool can be adjusted. An auto switch for detecting a tool can be mounted. (Series MA3 only) (Series MA3 only) Rotary actuated type MHR2-10 15 Refer to AHC system Series MA. 12-12-17
Double piston construction achieves compact design with strong gripping force. q r Mounting is possible from 4 directions. e w Model Bore size Gripping force (N) q w MHF2-8D MHZ2-10D 8 10 19 11 MHF2-12D MHZ2-20D 12 20 48 42 w e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 12-3-3 4 Series MHF2 Model Selection Model Selection Selection Procedure Confirm gripping force Confirm
Double piston construction achieves compact design with strong holding force. q r Mounting is possible from 4 directions. e w Model Bore size Holding force (N) q w MHF2-8D MHZ2-10D 8 10 19 11 MHF2-12D MHZ2-20D 12 20 48 42 w e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 Features 2 Series MHF2 Model Selection Model Selection Selection procedure Confirm gripping force Confirm
Test range Thermometer Equipment for test Pressure tap Pressure tap Restrictor in the downstream side Restrictor in the upstream side Flow meter 6d 2d 10d 20d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 20 Flow Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 16 to 20.
MHT MHY e MHW w -X Model Bore size Gripping force (N) q w MRHQ MHF2-8D MHZ2-10D 8 10 19 11 MA MHF2-12D MHZ2-20D 12 20 48 42 Dw e r MHF2-16D MHZ2-25D 16 25 90 65 MHF2-20D MHZ2-32D 20 32 141 158 447 Series MHF2 Model Selection Model Selection Selection Procedure Confirm gripping force Confirm external force on fingers Confirm gripping point Step 1 Step 2 Step 3 Confirmation of Gripping Force