Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: M9PA, Lead Wire Length(m):
Mounting: B (Tapped on Both Sides), Bore Size: 12mm, Stroke: 125mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: L (3m), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Mounting: F (Front Flange), Bore Size: 20mm, Stroke: 125mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: L (3m), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Clevis Width: 19.5mm, ø50, ø63, Bore Size: 50mm, Port Type: Rc1/4, Stroke: 125mm, End Bracket: None, Option: Foot, Locking Direction: Extension Locking, Unlock Port Position: -, Switch Mounting Rod Position: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Switch Mounting Rod: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: M9BAV, Lead Wire Length(m)
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: M9BW, Lead Wire Length(m)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: A93, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: A73, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: M9PA, Lead Wire Length(m):
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an
The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.Stroke reading cylinder with position feedback, Resolution: 0.1mm, Water resistance improved by changing sensor unit filter, Power supply