Mounting: B (Tapped on Both Sides), Bore Size: 20mm, Stroke: 25mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: L (3m), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Mounting: B (Tapped on Both Sides), Bore Size: 20mm, Stroke: 175mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: 0.5m, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Mounting: B (Tapped on Both Sides), Bore Size: 20mm, Stroke: 200mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: 0.5m, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Mounting: Tapped on Both Sides, Bore Size: 20mm, Stroke: 200mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: 0.5m, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: M9B, Lead Wire Length(m):
Item Display Content Setting of connection product [4L] 4 L range [16L] 16 L range [40L] 40 L range [PFW] is selected [100L] 100 L range [250L] 250 L range [10L] 10 L range [rAnG] [50L] 50 L range Selection of flow range [100L] 100 L range [PFA] is selected [200L] 200 L range [500L] 500 L range [4L] 4 L range [PFd] is selected [16L] 16 L range [40L] 40 L range Press the SET button to set.
PF2A30 series PF2A31 series 1 to 10 L/min type (PF2A510) 5 to 50 L/min type (PF2A550) [11L]: [21L]: [51L]: 10 to 100 L/min type (PF2A511) 20 to 200 L/min type (PF2A521) 50 to 500 L/min type (PF2A551) [10L]: [50L]: PF2W30 series PF2W33 series [11L]: 10 to 100 L/min type (PF2W511) 0.5 to 4 L/min type (PF2W504) [04L]: [20L]: [40L]: 2 to 16 L/min type (PF2W520) 5 to 40 L/min type (PF2W540) PF2D30
PF2A20 series 1 to 5 to 10 L/min type (PF2A510) 50 L/min type (PF2A550) [10L]: [50L]: [11L]: [21L]: [51L]: 10 to 20 to 50 to 100 L/min type (PF2A511) 200 L/min type (PF2A521) 500 L/min type (PF2A551) PF2W20 series 0.5 to 4 L/min type (PF2W504) (PF3W504) [04L]: [20L]: [40L]: [11L]: 2 to 5 to 16 L/min type (PF2W520) (PF3W520) 40 L/min type (PF2W540) (PF3W540) 10 to 100 L/min type (PF2W511)
Filter Rc1/2 20m HRS-PF003 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #40 Install either the strainer or filter.
Note 1 Valve Rc1/2 2 Filter Rc1/2 20m HRS-PF003 If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more HRS-R Series 3.4 Piping 3-21 HRX-OM-W058 Chapter 3 Transport and Setting Up 3.5 Fill of circulating fluid Turn the tank lid anticlockwise to open.
Filter Rc1/2 HRS-PF003 or 20m HRS-PF004 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more HRS-R Series 3.4 Piping 3-21 HRX-OM-X027 Chapter 3 Transport and Setting Up 3.5 Fill of circulating fluid Turn the tank lid anticlockwise to open. Supply the circulating fluid up to the H mark on the fluid level indicator.