L M9BWL 5 m . Z M9BWZ Auto Switch Proper Mounting Position for Stroke End Detection and Its Height D-A93/M9B Minimum Stroke for Auto Switch Mounting Unit: mm 22 Hs B A Auto switch 1 pc. 2 pcs. (Different surfaces) 2 pcs.
(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) Nil XL H0 Solid state auto switch y Number of auto switches/Detecting position XLQ Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Pre-wire connector Special function Type Electrical entry Indicator light Wiring (Output) 3 (L) 5 (Z) Applicable load 0.5 (Nil) AC DC Perpendicular In-line M9N M9P M9B F8N F8P F8B 3-wire (NPN) Solid state switch Relay, PLC 12 V 24 V Yes Grommet 3-wire (PNP) 2-wire Auto switches marked with are produced
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
L D-M9P (Example) Nil Lead wire length 0.5 m 3 m L 5 m Z A contact protection box should be used in any of the above situations. The lifetime of the contact may be shortened. D-A72 (H) must be used with the contact protection box regardless of load styles and lead wire length. None N Applicable for the connector style (D-C) only.
Mass (g) Auto Switch Internal Circuit D-M9N D-M9P D-M9B Auto switch model 0.5 8 8 7 D-M9N 1 14 14 13 Lead wire length (m) DC (+) Brown 3 41 41 38 5 68 68 63 Main circuit of switch OUT Black Dimensions (mm) DC () Blue D-M9l M2.5 x 4 l Slotted set screw D-M9P DC (+) Brown Indicator light 2.6 Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 DC () Blue VNA D-M9B VNB 3.2 OUT
light M2.5 x 4 l Slotted set screw 8 DC () Blue 2 3.2 4.6 4 D-M9B(V) 2.7 2.8 20 OUT (+) Brown 2.6 9.5 OUT () Blue 4 6 Most sensitive position 11 2-Color Indication Solid State Auto Switch Direct Mounting Style D-M9NW(V)/D-M9PW(V)/D-M9BW(V) Refer to SMC website for the details of the products conforming to the international standards.
(Except 50) MY1MW16, 20, 50, 63 MY1CW16, 20, 50, 63 Side port Side port Front port Front port L L L L L L R R R R R R R L L R R R L L Bottom port Bottom port L R Slide table operating direction MY1MW25, 32, 40 MY1CW25, 32, 40 L L This port cannot be used.
Data MY1B16 to 100 MY1M16 to 63 MY1C16 to 63 MY1H16 to 40 L L R L L L L R R R R R L R R L Note 2) Note 2) R R L L O-ring L R Slide table operating direction Piping tube Note 2) For bottom piping, refer to the figure above.
L (Example) M9BWL 5 m . Z (Example) M9BWZ Auto Switch Mounting Position (Detection at Stroke End) and Its Mounting Height D-A93/M9B Minimum Stroke for Auto Switch Mounting Unit: mm Auto switch 1 pc. 2 pcs. (Different surfaces) 2 pcs.
5: LEYG16 B M L Lead 5: LEYG16 AB M L Lead 10: LEYG16 AA M L 4.4 4.4 Lead 10: LEYG16 A M L 0 0 600 0 100 200 300 400 500 600 0 100 200 300 400 500 Speed [mm/s] Speed [mm/s] LEYG25 l M LEYG25 Al M L L 33 66 Lead 3: LEYG25 C M L Lead 3: LEYG25 AC M L Vertical work load [lb] Vertical work load [lb] 22 44 Lead 6: LEYG25 B M L Lead 6: LEYG25 AB M L 11 22 Lead 12: LEYG25 A M L Lead 12: LEYG25 AA
Securing the unit body Stroke Adjustment Unit Tightening Torque for Fixing Bolts Unit Tightening torque Unit: Nm Bore size (mm) L H L H L H L H 16 0.7 25 3.5 40 13.8 63 27.5 Absorber fixing bolt Adjustment bolt lock nut Stroke adjustment unit fixing bolt Shock Absorber Tightening Torque for Fixing Bolts Unit: Nm Shock absorber Unit Tightening torque Bore size (mm) L H L H L H L H 16 0.6 25
LEL25MT-100l-l LEL25MT-200l-l LEL25MT-300l-l LEL25MT-400l-l LEL25MT-500l-l LEL25MT-600l-l LEL25MT-700l-l LEL25MT-800l-l LEL25MT-900l-l LEL25MT-1000l-l LEL25LT-100l-l LEL25LT-200l-l LEL25LT-300l-l LEL25LT-400l-l LEL25LT-500l-l LEL25LT-600l-l LEL25LT-700l-l LEL25LT-800l-l LEL25LT-900l-l LEL25LT-1000l-l With motor cover 272.5 372.5 472.5 572.5 672.5 772.5 872.5 972.5 1072.5 1172.5 292.5 392.5
125 100 D M9B M9B With Auto Switch CDLS M9BW L 125 100 D With auto switch (Built-in magnet) Cylinder unit auto switch Port thread type Nil TN TF Lock unit auto switch Nil Without auto switch Mounting style B L F G Rc NPT G Nil Without auto switch Select applicable auto switches from the table below.
Table Displacement (Reference Value) L W 1 N = 0.224 lbf 0.02 LEJ;40 Displacement [mm] (L = 52.5 mm) LEJ;63 (L = 64.5 mm) 0.01 0 0 100 200 300 400 500 Load W [N] Note) This displacement is measured when a 15 mm aluminum plate is mounted and fixed on the table.
m Dd9 L (Drill through) 3 x 18 l 4 x 25 l 4 x 35 l 4 x 36 l 0.040 0.076 CD-M03 CD-M05 CD-M08 CDP-7A 10 14 22 25 20, 25 32, 40 50, 63 80 3 4 4 4 4 4.5 5 5 36 51 72 78 44 60 82 88 0.050 0.093 0.065 0.117 0.065 0.117 l m L Note) When using cotter pins, flat washers are used together.
F G Solid state M9B, M9BW, K59, K59W Nil F Male rod end Female rod end Nil S n 2 pcs. 1 pc. n pcs.
Allowable overhang L [mm] Allowable overhang L [mm] 167 Model Selection MXQ Series Determine the overhang.
L D-A73 (Example) MHY Lead wire length MHW 5 m None Nil L 0.5 m 3 m Z N MRHQ Applicable for the connector type (D-C) only.