SMC Corporation of America
Elite Part Number Search
Search Results "CDPX2N15-50-A73H"

Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Made to Order: Individual Specifications (For details, refer to pages 1538 and 1539.) 6 10 300 500 50, 100, 150, 200 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350 400, 450, 500 Symbol Specifications -X116 -X168 -X322 -X431 Hydro specifications 15 750 Helical insert thread specifications 20 25

Standard Strokes Standard strokes (mm) Bore size (mm) 20 32 40 50 63 80 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 JIS symbol 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Double acting/Double rod 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25,

5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 6 Series CQ2Y Mounting bracket dimensions are the same as those of the anti-lateral load type of Series CQ2S.

Q + Stroke (NA) Cylinder form 12 16 (mm) d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 x 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 x 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 x 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90

DGraph (2) Cylinder Output on the Retracting Side (Double acting) 20150 1500 Tube bore size [mm] 100 1000 40 Side load Balance weight 40 50 400 500 32 20 25 30 200 250 300 Operating pressure [MPa] Cylinder output F[N] Load weight [kg] 15 150 Allowable Side Load on the Piston End (Nm) 10 100 Stroke of linear part Size 40 5 10 15 20 25 30 40 50 75 100 4 5 40 50 32 40 14 14 13 13 13 12 12 11

Q + Stroke (NA) Cylinder form 12 16 d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 x 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 x 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 x 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90 54 9

Bore size (mm) Standard stroke (mm) Minimum Operating Pressure (MPa) 20, 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Bore size (mm) 12 16 20 25 32 40 50 63 80 100 0.07 0.05 Pneumatic (Non-lube) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 0.18 0.10 Air-hydro 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 50, 63 80, 100 Manufacture of Intermediate Stroke Spacer is installed in the standard

Suction flow rate of vacuum suction type (Reference values) Specifications Bore size Suction flow rate l/min (ANR) 40 50/63 Bore size (mm) Item 40/50/63 10 20 1.5MPa 1.0MPa 0.05MPa Proof pressure Maximum operating pressure Minimum operating pressure Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Ambient and fluid temperature 50 to 400 mm/s Stroke length tolerance

Calculation methodExample: MDLUL32-100 Basic weight0.72 (axial foot typesize32) Additional weight0.16/50 stroke Stroke100 stroke 0.72 +100/50 x 0.16 = 1.04kg 2

32, 40, 50, 63 Series MHT2 RoHS How to Order M9BW 32 2 MHT DZ Made to Order (Refer to page 645 for details.)

CVS1K 40, 50 63, 80 100 J Standard 10-15-67 Double acting DNonrotating rod 40, 50 63 10-15-78 -X Series MVGQ 2012, 16 20, 25 32, 40 50, 63 80, 100 Data 10-16-1 Double acting 10-15-1 Series CV Valve Mounted Cylinder Precautions Be sure to read before handling.

CVS1K 40, 50 63, 80 100 J Standard 10-15-67 Double acting DNonrotating rod 40, 50 63 10-15-78 -X Series MVGQ 2012, 16 20, 25 32, 40 50, 63 80, 100 Data 10-16-1 Double acting 10-15-1 Series CV Valve Mounted Cylinder Precautions Be sure to read before handling.

Standard strokes (mm) Bore sizes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 50, 63 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Example) For CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke CQ2XB40-75D cylinder. Specific Product Precautions Be sure to read before handling. Refer to pages 15 to 24 for safety instructions and precautions.

Example of AND (Series) and OR (Parallel) Connection When using solid state auto switches, ensure the application is setup so the signals for the first 50 ms are invalid.

Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Made to Order: Individual Specifications (For details, refer to pages 1538 and 1539.) 6 10 300 500 50, 100, 150, 200 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350 400, 450, 500 Symbol Specifications -X116 -X168 -X322 -X431 Hydro specifications 15 750 Helical insert thread specifications 20 25

15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) D-H7m/H7mW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) D-C73C D-C80C D-H7C 10 15 65 15 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 27.5 (n 2) (n = 2, 3, 4, 5) D-M9mV 5 5 10 + 10 (n 2) (n = 4, 6) Note 4) D-A9mV 5 10 10 + 15 (n 2) (n = 4, 6) Note 4) D-M9m D-A9m 10

Cylinder bore 32 mm 40 mm 50 mm 63 mm Auto switch is attachable. 32 40 50 63 Action Double acting D Auto Switch Specifications / Refer to p.2.11-1 for further information of auto switch.