Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Speed, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Specification: Built-in magnet, Auto Switches: M9PW
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 200mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Rubber Bumper
Bearing Style: Ball Bush Bearing, Bore Size: 40mm, Port Type: NPT, Stroke: 200mm, Z: Z, Locking Direction: Retraction Stroke Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Bearing Style: L (Ball Bush Bearing), Bore Size: 40mm, Port Type: TN (NPT), Stroke: 200mm, Z: Z, Locking Direction: B (Retraction Stroke Lock), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 200mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable CJ2, low friction type, Mountings: basic, foot
Magnet: Built-in Magnet, Series: J2X, Mounting: Double Clevis, Bore Size: 16mm, Stroke: 125mm, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Rail Mounting
Magnet: Built-in Magnet, Series: J2X, Mounting: Double Clevis, Bore Size: 16mm, Stroke: 15mm, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Rail Mounting
Magnet: Built-in Magnet, Series: J2X, Mounting: Double Clevis, Bore Size: 16mm, Stroke: 30mm, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Rail Mounting
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 15mm, Head Cover Port: 90° to Axis, Auto Switch: F7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 100mm, Head Cover Port: 90° to Axis, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 150mm, Head Cover Port: 90° to Axis, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 200mm, Head Cover Port: 90° to Axis, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 45mm, Head Cover Port: 90° to Axis, Auto Switch: A (Rail Mount Type Switch Mounting)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 60mm, Head Cover Port: 90° to Axis, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Speed, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Specification: Built-in magnet, Auto Switches:
Magnet: D (Built-in Magnet), Series: J2X, Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 125mm, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Magnet: D (Built-in Magnet), Series: J2X, Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 15mm, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)