Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm
27.5 B 17 19 18 23.5 A 13.5 11.5 18.5 23 B 12.5 14.5 13.5 19 B 9 11 10 15.5 B 7 9 8 13.5 B 13 15 14 19.5 A 14.5 12.5 19.5 24 B 13.5 15.5 14.5 20 B 7.5 9.5 8.5 14 B 10.5 12.5 11.5 17 B 7 9 8 13.5 A 8 6 13 17.5 A 14 12 19 23.5 A 8.5 6.5 13.5 18 A 11.5 9.5 16 21 A 8 6 13 17.5 20 25 32 40 Note) When setting an auto switch, be sure to check its operation before adjusting.
B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model A/B/C side Port side Port/A/B/C side Port/A/B/C side BQ-2 BQ2-012 Two kinds of auto switch brackets are used as a set.
D-M9 A/D-M9 AV (With indicator light) D-M9NAV V A B 9 M D A B 9 M D A N 9 M D D-M9PAV D-M9PA Auto switch part no.
A B Hs Hs Hs Hs Hs Hs Hs Hs Hs Hs D-M9lV D-M9lWV D-M9lAV D-A9lV D-M9lV D-M9lWV D-M9lAV D-A9lV 17 B A A B D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 D-F7l D-F7lW D-J79 D-J79W D-F7BA D-F79F D-A7lH D-A80H 17 A B A B D-F7lV D-F7lWV D-F7BAV D-A7l D-A80 D-A79W D-H7C 17 A B A B D-C73C D-C80C D-J79C D-A73C D-A80C 17 Auto Switch Made to Order B A B A 102 C85/C75 Series Auto Switch Proper Mounting
A B B B A B A B A B A B A 20 25 32 40 6.5 5.5 10.5 9.5 1 0 6 4 3 0.5 0 6 5 2.5 1.5 7 6.5 5.5 10.5 9.5 1 0 6 4 3 0.5 0 6 5 2.5 1.5 7 7.5 6.5 11.5 10.5 2 1 7 5 4 1.5 0.5 7 6 3.5 2.5 8 13.5 11.5 17.5 15.5 7 6 12 10 9 6.5 5.5 12 11 8.5 7.5 13 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model Port side Port/A/B/C side A/B/C side Port/A/B/C side BQ-2 BQ2-012 Two kinds of auto switch brackets are used as a set.
A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.