SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2D10-30Z-V-M9P-A"

Order auto switch mounting brackets separately when D-A9(V)/M9(V)/M9W(V)/M9A(V) types are mounted with a rail.

(mm) Auto switch model Bore size (mm) 20 25 32 40 D-M9l(V) D-M9lW(V) D-A9l(V) Auto switch model Bore size 20 25 32 40 D-A9l(V) 6 6 6 6 BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) D-M9l(V) D-M9lW(V) D-M9lA(V) 3 3 4 3.5 D-M9lA(V) Note 2) BM5-020S (A set of b, c, d, e) BM5-025S (A set of b, c, d, e) BM5-032S (A set of

) 12 V 5 V, 12 V IC circuit Diagnosis (2-color indication) Grommet Yes Relay, PLC 3-wire (PNP) 24 V 2-wire 12 V 3-wire (NPN) 5 V, 12 V IC circuit Water resistant (2-color indication) 3-wire (PNP) 2-wire 12 V Auto switches marked with a symbol are produced upon receipt of order.

field resistant (2-color indication) 3-wire (Equiv. to NPN) A96 5 V IC circuit Yes A93 A90 A54 A64 IC circuit 100 V A33 A34 A44 Grommet No 100 V or less Reed switch Relay, PLC Yes 12 V 100 V, 200 V No 200 V or less 24 V 2-wire Terminal conduit PLC Yes 100 V, 200 V DIN terminal Relay, PLC Diagnostic indication (2-color indication) A59W Grommet Solid state auto switches marked with a

switch Reed switch Relay, PLC 12 V Grommet 24 V Yes 5 V, 12 V Diagnostic indication (2-color indication) 12 V IC circuit IC circuit 3-wire A96 A96V (NPN equivalent) 5 V 12 V Yes 24 V Grommet Relay, PLC A93 A90 A93V A90V 100 V 2-wire No 100 V or less Solid state auto switches marked with are produced upon receipt of order.

Most sensitive position Most sensitive position 2.7 12.5 12.5 D1799 How to Mount and Move the Auto Switch Mounting Bracket Direct Mounting Style Solid state D-M9N(V), D-M9P(V), D-M9B(V), D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NA(V)L, D-M9PA(V)L, D-M9BA(V)L Reed D-A90(V), D-A93(V), D-A96(V) Solid state D-M9N(V), D-M9P(V), D-M9B(V), D-M9NW(V),

How to Order M9N A 25 XMD XYD Angle type M9N A 25 In-line type 1 2 3 4 5 6 7 2. Flange type 1. Flange size XMD Symbol Nil D C Type KF (NW) K (DN) CF Applicable flange size 25, 40, 50, 63, 80 63, 80 40 (070), 63 (114) XYD V V V V V XMD V V V V V Size 25 40 50 63 80 XYD Nil D KF (NW) K (DN) 25, 40, 50, 63, 80 63, 80 3.

Low Speed Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) MQ BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) RHC D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b,

Auto switch model Tightening torque D-M9 (V) D-M9 W(V) 0.89 to 1.33 lbf in (0.10 to 0.15 Nm) Flat head watchmakers screwdriver (not an accessory) 5 to 6 Note) When tightening the auto switch mounting screw, use a watchmakers screwdriver with a handle diameter of about 5 to 6 mm. 61 Solid State Auto Switch Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS LEFS LEFB LEJS LEJB LEY LEYG LECYM

RZQ Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL MI W S CEP1 CE1 Auto Switch Mounting Bracket Part No.

MLGP Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL RLQ MLU ML1C Auto Switch Mounting Bracket Part No.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

Note 2) When setting an auto switch, confirm the operation and adjust its mounting position. 49 Series NCM Auto Switch Proper Mounting Position and Its Mounting Height (Double rod) D-M9(V)/M9W(V) D-A9(V) HS HS 0.66 0.66 A 0.88 B A 0.88 B (0.98) ( ):D-A93 HS D-C7/C8 0.66 HS A 0.88 B 0.63 1.02 A B D-H7/H7W/H7NF/H7BAL D-B5/B6/B59W HS HS 0.96 SMC SMC 0.63 1.30 A B B A (1.42) 1.14 D-G5NTL

(Tightening torque of M2.5 screw should be 0.1 to 0.2 Nm.) 20 Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Data Auto Switch Mounting Bracket Part No.

Solid state switch D-M9 (V) D-F9 W(V) B A B A HS 056 HS B A B A 075, 106 HS B A B A 150, 200, 250 Note 1) Figures in the table below are references for auto switch mounting positions in the stroke end detection.

Inrush Current Flow Time (Reference) 200 V Current 100 V 0 5 15 10 20 25 30 Time [Second] 2 Mounting position of the heater Heater symbol XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 H4 (100C) (a) (a) (b), (c) (a), (b), (c) H5 (120C) (a) (b), (c) (b), (c) (a), (b), (c) (b), (c) (b) (a) (c) Heater (Option) 17 Aluminum High Vacuum Angle Valve: With Heat-resistant Auto Switch XLm Series Made to

Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S

(Allen-Bradley) MP-/VPMP/VP V TL TLY-A V V AM AM30 V V Beckhoff Automation GmbH AM AM31 V V AM AM80/AM81 V V Siemens AG 1FK7 1FK7 V V Delta Electronics, Inc.