SMC Corporation of America
Elite Part Number Search
Search Results "CDBG1FA25-50-HN-H7B"

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Auto Switches: H7B

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 125mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 400mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 400mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs., Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting Bracket: -

Basic 1.2 1.62 2.04 3.2 Basic weight Axial foot 1.44 1.88 2.44 3.72 Flange 1.29 1.79 2.23 3.47 Weight for additional stroke per 50mm 0.06 0.08 0.09 0.15 Calculation example: RHCL32-600 PBasic weight 2.44 (Foot style 32) PBasic weight 0.09/50 Stroke PCylinder stroke600 Stroke 2.44+0.09 X 100/50=2.62kg 4.10-5 High Power Cylinder Series RHC Front flange Rc(PT)P GB Rc(PT)P GA 4-R chamfer 4-FD

Standard Strokes Bore size (mm) 20 32 40 50 63 80 100 Standard strokes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Made to Order 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Page 34 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 JIS symbol 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30

185 185 190 20 25 32 40 24 24 24 25 36 36 36 46 With rod boot (mm) ZZ Symbol Z 1 to 50 143 147 149 181 l 1 to 50 63 67 67 71.5 Stroke 1 to 50 12.5 12.5 12.5 12.5 Bore 51 to 100 25 25 25 25 101 to 150 37.5 37.5 37.5 37.5 151 to 200 50 50 50 50 201 to 300 75 75 75 75 51 to 100 76 80 80 84.5 101 to 150 88 92 92 96.5 151 to 200 101 105 105 201 to 300 126 130 130 51 to 100 156 160 162 194 101

for 25 and 32, 55% for 40 and 60% or less for 50, respectively.)

5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 6 Series CQ2Y Mounting bracket dimensions are the same as those of the anti-lateral load type of Series CQ2S.

P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 10-4-7 8 Series CQ2Y Dimensions/63 to

26 28.5 33.5 M18 x 1.5 -X (mm) Without auto switch With auto switch A B A B 20U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5