Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting Bracket: -
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 25mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 25mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket:
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 25mm, Stroke: 250mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 25mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C
This is a legacy product, and replaced byCDG1LN32-150Z-H7BL-XC22, CYL, AIR, DBL ACT, AUTO-SW, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, LE, 32MM CG DBL-ACT AUTO-SW, 2.04897 lb
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 050 (1/2"), Port Location: R (In-line), Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M, Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 100 (1"), Port Location: Perpendicular, Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 100 (1"), Port Location: R (In-line), Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 150 (1 1/2"), Port Location: R (In-line), Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 200 (2"), Port Location: Perpendicular, Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 200 (2"), Port Location: R (In-line), Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 400 (4"), Port Location: Perpendicular, Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 400 (4"), Port Location: R (In-line), Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 500 (5"), Port Location: Perpendicular, Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 600 (6"), Port Location: Perpendicular, Auto Switch: H7BL--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 3M