Up to 700 25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.
, 200 201 to 350 D25 32 40 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200, 250, 300 -X Intermediate stroke is available, too. 20Applicable Auto Switch/Refer to page 9-15-1 for further information on auto switches.
Up to 700 45 25 150 Up to 700 25 45 MK(2) 1500 32 150 Up to 1000 32 50 RS Q G 40 200 Up to 1000 40 60 Note 1) The cylinder performance may not as expected when stroke is shorter than recommended stroke even they are available.
D-B54, B64, and B59W cannot be mounted for bore size 044 and 056. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN For details about auto switches with pre-wired connector, refer to Best Pneumatics catalog. D-A9, M9, M9W are shipped together.
Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.
150 With auto switch CA1 Number of auto switches S n Bore size 20mm 25mm 32mm 40mm CS1 Air cylinder with auto switch 20 25 32 40 2 1 n Without auto switch (Built-in magnet) Auto switch * Refer to the left table for selecting applicable auto switches.
50 Bore) Screw & Nut Kit included with cylinder Switch # Switch # Actuator Mounting Auto Switch Mounting Hardware (brackets,bands, screws & nuts) is identical to our CDS1 Tie Rod Mounting BT-12 (125/140 Bore) BT-16 (160 Bore) BT-18 (180 Bore) BT-20 (200 Bore) our new part # C95D Tie Rod Mounting BT-03 (32/40 Bore) BT-05 (50/63 Bore) BT-06 (80/100 Bore) -F5PSDPC NCDA1 Tie Rod Mounting NBT-150
Standard Strokes Bore size [mm] Standard stroke [mm] Note 1) Long stroke [mm] Note 2) 40 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500 800 Refer to pages 18 to 23 for cylinders with auto switches. 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500, 600 1200 Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at
-XA< Tie-rod, cushion valve, tie-rod nut, etc. made of stainless steel -XC7 (mm) Standard stroke Bore size Long stroke (L and F only) -XC8 -XC14 -XC15 -XC30 Adjustable stroke cylinder/Adjustable extension type 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Change of trunnion bracket mounting position Change of tie-rod length Rod trunnion 40 800 25, 50, 75, 100, 125, 150
Air Cylinder Short Type Standard: Double Acting, Single Rod Series CM3 20, 25, 32, 40 RoHS How to Order CM3 L 40 150 M9BW With auto switch CDM3 L 150 40 With auto switch (Built-in magnet) Number of auto switches Rod end thread Nil S n Mounting 2 pcs. 1 pc. n pcs.
Bore size (mm) Standard stroke (mm) Note 1) Long stroke (mm) Note 2) Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at stroke end) and mounting height Operating range Auto switch mounting bracket/Part no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600
Cushion adjustment (relief adjustment) man-hours are the same as the adjustment (cushion needle adjustment) for general purpose cylinders. 200 150 High power cylinder Quality of Cushioning (RHCF40-500, Load mass 5 kg, Supply pressure 0.5 MPa, Horizontal operation) Buffer capacity [J] 500 General purpose cylinder (50 mm/s) 100 3000 mm/s 2000 mm/s 1000 mm/s 400 500 mm/s Stroke [mm] 300 50 200
Y59B 21 C D A 2 B 40 150 Y59B Nil Built-in magnet Number of auto switches No 2 pcs. 1 pc.
C J G5-S 100 CV 250 = 0.7 200 MVGQ 0.5 0.1 0.3 150 CC 100 50 RB 0 1,000 2,000 3,000 J Maximum speed Vmax (mm/s) : Cylinder load ratio Vmax: Maximum speed (Refer to page 10-6-5.) D-X 20Data 10-6-19
Caution Standard stroke (mm) Note) Bore size (mm) 20 25 32 40 50 63 80 100 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 Note) Manufacture of intermediate strokes in 1 mm increments is possible. (Spacers are not used.)
, 200 201 to 350 D25 32 40 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200, 250, 300 -X Intermediate stroke is available, too.
CM2 A B Z 40 150 CDM2 With auto switch M9BW 150 A B 40 Z Port thread type Number of auto switches Rod end bracket With auto switch (Built-in magnet) Nil Rc TN NPT TF G Nil None V Single knuckle joint W Double knuckle joint Mounting Nil 2 pcs. S 1 pc. n n pcs.
, 200 Data D-C7/C8 D-B5/B6 D-H7 D-G5NTL 1500 10 mm 15 mm 25, 50, 75, 100, 125, 150, 200, 250, 300 15 mm 20 mm Note 1) Intermediate strokes other than the above are produced upon receipt of order.
Standard Strokes (mm) Bore size Standard stroke Note1) Maximum manufacturable stroke Note 2) 1 Cylinders with rubber bumper have no bumper. 2 Only compatible with cylinders with rubber bumper, but has no bumper. 20 25, 50, 75, 100, 125, 150, 200 201 to 1500 25 32 40 50, 63 80 100 25, 50, 75, 100, 125, 150, 200, 250, 300 301 to 1500 Refer to pages 355 to 361 for cylinders with auto switches
, 200 201 to 350 301 to 400 301 to 450 301 to 800 D-C7/C8 D-B5/B6 D-H7 D-G5NTL 1500 10 mm 15 mm 25, 50, 75, 100, 125, 150, 200, 250, 300 D-B59W 15 mm 20 mm Note 1) Intermediate strokes other than the above are produced upon receipt of order.