SOFT START UP VALVE, VALVE, SOFT START, 237, 1.53000 lb
VALVE, SOFT START SPL, VALVE, SOFT START, 1.75 lb
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)
Body Size: 5000, Port Thread: Rc, Port Size: 10 (1), Option: None, Voltage: 5 (24 VDC), Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Flow Direction: Left to Right
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: None
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: None
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: T (High-pressure Pump Mounted), Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Z (No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip)
Cooling Capacity: 012 [1000/1200 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Body Class: 6 (Class 6, Orifice ø22), Valve Type: 2 (Double Acting), Port Size: 10 (1), Thread: R, Rc, Material: A (Body: SUS, Endplate: PPS, Diaphragm: PTFE), Option: None, Specification: V (Vacuum)
Body Class: 6 (Class 6, Orifice ø22), Valve Type: 0 (Normally Closed), Port Size: 10 (1), Thread: R, Rc, Material: A (Body: SUS, Endplate: PPS, Diaphragm: PTFE), Option: None, Specification: V (Vacuum)
Body Size: 60 (1), Thread: Rc, Port Size: 10 (1), Mounting: w/o Mounting, Flow Direction: Left to Right, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa
Body Size: 50 (3/4), Thread: Rc, Port Size: 10 (1), Mounting: w/o Mounting, Flow Direction: Left to Right, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa