A Unused A Unused A Unused A Unused A Unused VQC A B A B A B A B A B A A A B A B A B A A A A SQ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 6 7 8 9 10 11 12 13 14 15 0 0 1 2 3 4 5 VQ0 Type SC OMRON Corporation SYSBUS Wire System Type SD SHARP Corporation Satellite I/O Link System VQ4 VQ5 ADDRESS NO. STATION NO.
23 41.2 26.1 62.5 15.6 46 (46) AS331F-03-07(S)A 1/4" 3/8 19 11.2 12.9 16.6 20.2 36 21.4 50.1 42.3 40.7 37.1 35.5 13.3 34 (35) AS331F-03-09(S)A 5/16" 13.2 37.1 23.5 52.2 14.2 35 (36) AS331F-03-11(S)A 3/8" 15.9 17.4 23 41.2 26.1 54.8 15.6 38 (39) AS431F-04-11(S)A 3/8" 1/2 24 (23.8) 15.9 17.4 18.8 25.6 46.4 (46.3) 26.1 61.2 50.8 49.2 43.7 42.1 15.6 61 (59) AS431F-04-13(S)A 1/2" 18.5 21 26.2
OUT2 NC Sensor 8 Load 41.8 4 40.3 OUT1 40 4.3 Black Main circuit 7 3 Load Brown 6 2 + SMC FLOW SWITCH Blue 5 1 35.8 36 12 to 24 VDC Series PF2W5 A 40 UNIT RESET PF2W30-A SET Panel fitting dimension 3 x 7.2 (= 21.6) 8-M3 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black 1 2 3 4 Main circuit 7 3 Load +0.5 0 Brown 19.4 6 2 + Blue 5 1 12 to 24 VDC 5 6 7 8 Series PF2W5 PF2W31-A View A The applicable
Molded-case circuit breaker (Note 1, 3) Fuse Frame, rated current Magnetic contactor Driver Voltage Voltage AC [V] Class Current Power factor Power factor (Note 2) [A] AC [V] Improving reactor is Improving reactor is not used used LECSS2-T5 30 A frame 5 A S-N10 10 LECSS2-T7 LECSS2-T8 30 A frame 10 A 30 A frame 5 A 15 Mitsubishi 240 T 300 Electric Corporation LECSS2-T9 30 A frame 15 A 30 A
Reed switch Solid state switch A B HS D-F7 D-J79 D-F7W D-J79W D-F7BAL D-F79F D-F7NTL D-A7H D-A80H 32, 40 D-F7, D-J79W D-J79, D-F7BAL D-F7W, D-F79F D-F7NTL Auto switch model D-A7H D-A80H A B Hs A B Hs A B Hs Symbol Standard Stroke Bore size (mm) 32 40 9.5 13.5 32.5 36 6.5 9 6.5 9 32.5 36 9.5 13.5 10.5 13 32.5 36 14.5 18.5 Long Stroke Bore size (mm) 32 40 10 13.5 32.5 36 18 24 10 13.5 18 24
When using a differential pressure indication switch and if a filter clogged signal is incorporated into the sequence circuit of the machine, make sure to design the system so the filter clogged signal does not operate until normal operation starts. 10 Pressure drop (kPa) -04/06/08 -10/12/16 -20/24 COM. N.O. N.C.
10 stations A, B P , EA, EB Symbol 04 06 Thread type Symbol 1 2 Nil Rc 3 4 3 4 Passage Porting specifications (A, B) EA, EB P G F Symbol M Mixed N NPT For bottom ported: 1/2 only.
2 A A-A' Piston rod section A' !1 !3 !4 Component Parts Note Description Material No.
Piping port 3 8 03 04 06 1 2 3 4 3-5-79 80 Series VFR5000 Construction 2 position single 2 position double VFR520 VFR510 (B) (A) 4 2 (B) (A) 4 2 (EA)(P)(EB) 5 1 3 (EA)(P)(EB) 5 1 3 r u e t r u q o e !
AV*-OMZ0091-A PRODUCT NAME Soft Start-up Valve MODEL / Series / Product Number AV2000-(F,N)02(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV3000-(F,N)03(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV4000-(F,N)04(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV5000-(F,N)06~10(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AVA2000-(F,N)02(B,G,S)(-R,Z)-A AVA3000-(F,N)03(B,G,S)(-R,Z)-A AVA4000-(F,N)04(B,G,S)(-R,Z
MM R1 MM CJP ND E1 NX1 A U1 R2 H Z E1 NX U1 LB A A NX A1 CJ2 A1 U1 LB JCM Part no.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
ON OFF 4 36 4 (3) 0r/min (10ms) ON OFF ()ON MBR (MBR) OFF (ON) ALM (OFF) (ON) RX(n1)A RX(n3)A (OFF) . ON OFF (4) (10ms) 1560ms (1) 0r/min ON OFF 10ms MBR (2)ON (MBR) OFF (ON) ALM (OFF) (ON) RX(n1)A RX(n3)A (OFF) ON OFF 1.. 2.
single 2 position double 1/4, 3/8, 1/2 [4 (A), 2 (B) port] 1/4, 3/8, 1/2 [4 (A), 2 (B) port] 02 03 04 VFA5244(-P) 02 03 04 VFA5144(-P) 36 (39.5) 27 (31) 36 (39.5) 27 (31) SYA 14 (15.5) 14 (15.5) SYJA 20.5 (24.5) 20.5 (24.5) VZA 92 (100) 1/8 [Pilot port: Lateral (-P)] 1/8 [Pilot port: Lateral (-P)] VFA VFA 82 (87) 51.5 (55.5) 82 (87) 5 (6.5) 51.5 (55.5) VFRA 2B 4A 2B 4A VPA4 42 (45) 52 (58
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
D-A59W D-Z7/Z80 D-M9/M9W D-M9A Bore size (mm) Bore size (mm) D-Z7/Z80 D-A5/A6 Ht 23 28.5 36 42 54 Ht 23 28.5 36 42 54 Hs 29 37 42.5 54 62.5 B 8 10.5 9.5 11.5 13.5 A 10.5 19 19 21 24 27.5 Hs 25 29 37 43 54 Hs 31 34 41 47.5 55.5 Hs 32.5 36 41 46.5 57 66 Ht 25 30 37.5 43.5 56.5 64.5 Hs 38.5 43.5 49 59.5 69 Ht 30 37.5 43.5 56.5 64.5 Ht 28.5 36 42 54.5 61.5 A 14 22.5 22.5 24.5 27.5 B