They conform to JIS B 8372 (Air pressure regulator).
Symbol 0 P Side 1 E Side Side Bottom (1) Side Other A, B Side Base specifications 9 2 1 Individual exhaust Common exhaust Note 1) Size of A, B port bottom ported: 3/8, 1/2 Option Stations 02 2 stations 10 10 stations How to Assemble Manifold To order valves and blanking plate assembly mounted onto the manifold, list valves and blanking plate assembly with manifold base part number.
Symbol 0 P Side 1 E Side Side Bottom (1) Side Other A, B Side 9 Note 1) Size of A, B port bottom ported: Rc 3/8, 1/2 Option Stations Base specifications 2 1 Individual exhaust Common exhaust 02 2 stations 10 10 stations How to Assemble Manifold To order valves and blanking plate assembly mounted onto the manifold, list valves and blanking plate assembly with manifold base part number.
Replacement while residual pressure is present in the product may cause injury or damage of the product. b. Precautions for membrane module removal When the filter and membrane air dryer is connected by spacer (modular connection), be sure to remove the membrane dryer before replacement. c.
Model Product series AC20/AC25/AC30/AC50/AC55/AC60 AC20A/AC30A/AC40A/AC50A/AC60A AC20B/AC25B/AC30B/AC50B/AC55B/ AC60B AC20C/AC25C/AC30C/AC40C AC20D/AC30D/AC40D AR20 (K) /AR25 (K) /AR30 (K) /AR40 (K) / AR50 (K) /AR55 (K) /AR60 (K) AW20 (K) /AW30 (K) /AW40 (K) /AW60 (K) F.R.L. combination Option/Part No.
SMC Regulator (With Backflow Function) AR20(K)-B To AR60(K)-B Series.Features· Specifications with a backflow function feature an inbuilt mechanism for quickly exhausting the air-pressure at the outlet side.
Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specifications: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specifications: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual, Calibration
Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel
Series: 25A-ISE20, Rated Pressure Range: CH (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specifications: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
Series: 25A-ZSE20, Rated Pressure Range: C (0 to -101 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: 02 (Rc1/4), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option
Set the expansion packing (ISA-7-B) in the concave of the SUP port for expansion switches. NOTE If the detection nozzle is exposed to splashes of water or cutting oil, do not allow backflow from the detection nozzle to the switch body. Install the switch body at a position higher than the detection nozzle wherever possible.
Refer to the AR-A/AR-B/AR-D series catalog excerpt, which has been reproduced below.
The part number of the standard AR20 to AR60 round type pressure gauge is “G36-10-01,” or “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
Refer to the AR-A/AR-B/AR-D series catalog excerpt, which has been reproduced below.
The part numbers of standard AR20 to AR60 round type pressure gauges are “G36-10-01” and “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
When assembling high-pressure special order products, AF20 to 60-*-A-X425 and AR20 to 60-*-B-X425, prepare a nipple for installation.
How to Order 25A-LEFS 25 H R B 200 S 1 6N 1 q r w e t u y i o !0 !1 !