Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature:
Note 3) Do not cut the tube. 1 Use the product in an operating environment where humidity is as low as possible. 2 The value at which the moisture control tube is bent or flattened at 20C. Be careful not to bend or flatten the tube and the inner sleeve even if the value is more than the minimum bending radius. 2 Inner sleeve R How to Order IDK 02 100 Moisture control tube O.D.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, HB, AS 1 INCH STANDARD (PT), 0.11023 lb
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, DB, AS 1/4INCH STANDARD (PT), .30112 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size (mm)Weight (g)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, CB, AS 1/8INCH STANDARD (PT), .19682 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size (mm)Weight (g)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, D7, AS 1/4INCH EUROPEAN, .25300 lb
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: C (Out 1: NPN; Out 2: Analog 1 to 5 V), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: E (Out 1: PNP; Out 2: Analog 1 to 5 V), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: E (Out 1: PNP; Out 2: Analog 1 to 5 V), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: E (Out 1: PNP; Out 2: Analog 1 to 5 V), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant), Push lock: A (Push-lock)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)