Auto Switch Rotation range / Actuation / most sensitive position D-M9 auto switch D-F8 auto switch Size Rotating Operation Operation A B angle Hysteresis Hysteresis angle angle (mm) (mm) angle angle m m 90 20.5 16.5 05 46 10 20 10 180 23.2 19.2 90 22.4 18.4 1 41 10 15 10 180 25.6 21.6 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotating
type D-Z7 type Note 1) Note 1) D-Z8 type D-A9 type D-F9 type D-Y6 type D-Y7 type Note 1) Vertical outlet types cannot be mounted.
GD Breaker Capacity and Sensitivity Current Sensitivity current IDFB4E to 37E IDFB55E, 75E Model Breaker capacity 10 A 30 mA Maximum operating pressure: 240 psi (1.6 MPa) 10 A 30 mA Replacement Parts Configuration Replacement part no.
(mm) Applicable fitting size d 3.2 L Weight (g) D A M Model Urethane Soft nylon Applicable tubing KAR23-04 9.6 4 33.5 34.5 36.5 18.5 18.5 17.5 18 15.5 3.4 2.9 2.0 1.8 5 KAR04-06 KAR04-08 5.6 5.6 6 8 10.4 4 16 12.8 KAR04-10 39.5 37 39.5 10 3.3 2.5 KAR06-08 8 18.5 KAR06-10 6 12.8 KAR06-12 42 4.7 12 20 17 10 3.0 13.1 13.1 Applicable fitting size d 8 KAR08-10 41 4.0 18.0 18.0 10 20 18.5 15.2
237 219 32.6 21 18.5 62.8 10 86.3 30 29.7 25 R3/8 65.5 67.6 60.1 27.7 61.2 53.7 20.6 221 239 22 34.4 20.9 64.6 12 239 21 257 62.8 32.6 18.5 10 86.3 30 29.7 25 R1/2 65.5 71.1 63.6 27.7 62.9 55.4 24.1 239 259 22 34.4 64.6 12 20.9 Note 1) d indicates the applicable tubing O.D.
2 15-9-102 12 Tamper Proof Dual Speed Controller with One-touch Fitting Dimensions Metric size M1 L3 L2 Applicable tubing O.D. d D1 L6 D2 L1 D4 L4 H (Hexagon width across flats) (Hexagon width across flats) D4 D3 A1 L5 A2 L6 T Metric Size Model H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 A1 A2 M1 T d 4 6 6 8 6 8 10 6 8 10 12 6 8 10 12 10 12 ASD230F-M5-04T ASD230F-M5-06T ASD330F-01-06ST ASD330F-01-08ST
Grommet: G Conduit: C 2-M 2-M L L K Approx. 300 K Q F D Approx. 280 D Q F C R C G (PF) 1/2 R E B A H E 2-P Port size A H 2-P Port size B DIN connector: D Conduit terminal: T 2-M 2-M L L K Cable 6.8 to 10 K 27.5 F F Q (Q) 34 S 25 U R C R C G (PF) 1/2 (44) E B A H D (S) E G (PF) 1/2 B A H D 2-P Port size 2-P Port size N.C.
Circulating FluidTypical Physical PropertyValues Fluorinated Fluids Density [kg/m 3] Physical property value Temperature 10C 20C 50C 80C Specific heat C [J/(kg K)] 1.87 x 10 3 0.87 x 10 3 1.80 x 10 3 0.96 x 10 3 1.74 x 10 3 1.05 x 10 3 1.67 x 10 3 1.14 x 10 3 Water Density : 1 x 10 3 [kg/m 3] Specific heat C: 4.2 x 10 3 [J/(kg K)] 133 Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A
The set value can be copied to up to 10 switches simultaneously.
IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PV D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA DC24V DC12V Relay PLC
V) 1 0 V 0.10 V 0.12 V 10 V 1: The analogue output current from the connected equipment should be 20 A or less when selecting 0 to 10 V.
D ZS-24-D ZS-35-C Panel mount adapter E ZS-35-D ZS-35-F Panel mount adapter + Front protective cover F ZS-35-G Accessories 1 / Part numbers Part number Option 1 ZS-24-A Bracket A with 2 mounting screws each of M3 x 5 L, M4 x 5 L ZS-24-B Bracket B with 2 mounting screws M4 x 5 L ZS-24-D Bracket D with 2 mounting screws each of M3 x 5 L, M4 x 5 L ZS-35-C Panel mount adapter (piping specification
D-M9(V) D-M9W(V) D-M9A(V) Auto switch mounting bracket part no.
MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
(mm) 4 6 8 10 12 Effective area (mm2) Nylon Urethane 2.6 2.6 6.8 6.8 16.2 13.1 25.6 20.4 35.4 30.4 Note) Weight (g) A L D M Model d KCJ04-99 KCJ06-99 KCJ08-99 KCJ10-99 KCJ12-99 9 13 20 33 43 Note) D: Max. diameter 33.5 37 42.5 49.4 52.4 49.5 54 61 70.4 74.4 9.8 11.8 14 17 19 18 19 21.5 24 25.5 4 6 8 10 12 Applicable fitting Bulkhead Union: KCE H (width across flats) Effective area (mm 2)
F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
(Maximum 10 stations) Example) IITV00-05-07 02 03 2 stations 3 stations Indicate part numbers in order starting from the first station on the D side. 10 10 stations Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. One-touch fitting size for supply/ exhaust parts (End plate) The asterisk () specifies mounting.
10 to 300 701800 Note2) Stroke 30 to 930 20 to 620 10 to 300 801900 Speed range [mm/s] 30 to 780 20 to 520 10 to 250 9011000 30 to 660 20 to 440 10 to 220 10011100 Actuator specification 30 to 570 20 to 380 10 to 190 11011200 20 to 500 30 to 500 10 to 250 1000 Driver type LECPA Note2) Stroke 30 to 500 20 to 440 10 to 220 Speed 10011100 range [mm/s] 30 to 500 20 to 380 10 to 190 11011200
Operating Range The figure shows the mounting example for the D-M9(V)/ M9W(V)/ M9A(V)/ A9(V) Auto switch model Bore size (mm) 32 40 50 63 80 100 D-M9/ M9V D-M9W/ M9WV D-M9A/ M9AV 4 4.5 4.5 4.5 5 6 D-Y59/ Y69 D-Y7P/ Y7PV D-Y7W/ Y7WV D-Y7BA 5.5 5.5 7 7.5 6.5 5.5 D-F5/ J59 D-F5W/ J59W D-F5BA/ F5NT D-F59F 3.5 4 4 4.5 4.5 4.5 D-G39/ K39 9 9 9 10 10 11 D-P3DWA 3 4.5 4.5 5 5 5.5 D-P4DW 4 4 4 4.5
AC-OMQ0008-D PRODUCT NAME AIR COMBINATION MODEL/ Series AC10(A,B)-A AC20(A,B,C,D)-A AC25(B,C)-A AC30(A,B,C,D)-A AC40(A,B,C,D)-A Contents PAGE 1. PRECAUTION FOR SAFETY 18 2. APPLICATION 9 3. SPECIFICATIONS. . . 9 4. SERIESMAP AND COMBINATION OF EQUIPMENT. . . 10 5. HOW TO ORDER 1115 6. ATTACHMENTS / ACCESSORIESOPTIONSPART NUMBER 16 7. TROUBLE SHOOTING 16 8. SPARE PARTS LIST 16 9.