Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system

(R) 1 (P) Poppet VM200 2 port 3 port (A) 2 (A) 2 Side ported 1/4 Page 13 12 12 10 10 1 (P) 3 (R) 1 (P) VM400 3 port (OUT) 2 3 10 12 1 (N.C.)

M4 x 0.7 M5 x 0.8 M5 x 0.8 3.6 3.6 6 6 8 8 10 10 5 5 8 8 10 10 12 12 3 2 4 2.5 5 3.3 6.5 3.5 MHZ2-10-X51 +2.2 0 +2.2 0 +2.2 0 +2.2 0 +2.2 0 +2.5 0 +2.5 0 MHZ2-16-X51 MHZ2-20-X51 MHZ2-25-X51 Refer to pages 4 through 7 for the standard type dimensions, which are the same except for those shown above. 32 Series MHZ2/MHZJ2 Model Selection Method Model Selection Selection procedure Confirm gripping

/20. 9-1 9.1.2 HRR010-W-10/20. 9-3 9.1.3 Refrigerant with GWP reference . 9-5 9.1.4 Communication specification . 9-5 9.2 Outline dimensions . 9-6 9.2.1 HRR010-A-10/20. 9-6 9.2.2 HRR010-W-10/20. 9-7 9.3 Flow Chart . 9-8 9.3.1 HRR010-A-10/20. 9-8 9.3.2 HRR010-W-10/20. 9-8 HRR Series HRX-OM-X084 Contents 9.4 Cooling capacity . 9-9 9.4.1 HRR010-A -10. 9-9 9.4.2 HRR010-W-10. 9-9 9.4.3 HRR010-

set unit Note 1) Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Note 1) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse l/min, CFM x 10-2 l, ft3 x 10-2 l/min, CFM x 10-1 l, ft3 x 10-1 Display units Real-time flow rate Accumulated flow Note 1, 2) 0 to 9 l, 0 to 9 ft3 x 10-2 0 to 9 l, 0 to 9 ft3 x 10-1 Accumulated flow range Note 1) Power supply voltage Current consumption

Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18

50 50 Load weight m (kg) Load weight m (kg) 40 40 50 50 40 40 32 32 10 10 25 25 32 32 20 20 25 25 20 20 1 1 10 50 100 200 10 50 100 200 Eccentric distance l1 (mm) Eccentric distance l1 (mm) (16) Over 50 Stroke V = 400 mm/s (15) 50 Stroke or Less V = 400 mm/s 100 100 100 100 50 50 80 80 63 63 Load weight m (kg) Load weight m (kg) 50 50 10 10 40 40 32 32 25 25 1 20 20 1 10 50 100 200 0.7 10

to 63 20 20 CLQ 63 MLGP 50 RLQ 50, 63 50, 63 Load weight m (kg) 50, 63 MLU 10 10 50, 63 40 40 40 40 ML1C 50, 63 40 D40 -X 32 32 32 32 32 32 204 10 50 51 100 101 200 200 300 300 4 10 50 51 100 101 Data Stroke (mm) Stroke (mm) MLGPL80/100 MLGPL80/100 40 40 100 100 100 80 Load weight m (kg) Load weight m (kg) 100 80 80 80 100 100 80 10 10 80 6 10 100 200 200 300 300 25 26 50 51 6 10 100 25

5 $0 @8 #7 #6 $1 F G Area G (10) Enlarged view F 10, 15 w u i o !1 #2 q !3 r y e @6 @5 @3 $1 #0 @7 #1 10 Component Parts Note No. Description Material No.

10 10 10 ORIG ACC/DEC 1000 1000 1000 1000 Creep speed 10 10 10 10 ORIG sensor 0 0 0 0 ORIG SW Dir 0 0 0 0 Undefined parameter21 0 0 0 0 101 - Appendix 1.5 LER series setting value LER Step data default Model LER10K LER10J LER30K LER30J LER50K LER50J Gear Ratio [] 8 12 8 12 7.5 12 No. 0 0 0 0 0 0 Movement MOD ABS ABS ABS ABS ABS ABS Speed 280 420 280 420 280 420 Position 0.00 0.00 0.00 0.00

Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18

type LEPY Series Page 374 25 to 50 6.0 1.5 200 5 24 to 40 4.0 1.5 200 10 12.5 to 25 3.0 1.0 350 10 12 to 20 2.0 1.0 350 14 to 20 1.0 0.5 150 4 6 Slide table type LEPS Series 7 to 10 0.75 0.25 300 8 25 50 Page 383 25 to 50 2.0 1.5 200 5 24 to 40 2.0 1.5 200 10 12.5 to 25 1.5 1.0 350 10 12 to 20 1.5 1.0 350 370 LEPY/LEPS Series Mounting Variations Mounting from various directions Side mounting

Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.

End Plate EX600-ED2-l EX600-ED3-l Power connector Model specification M12 (5-pin) plug 7/8 inch (5-pin) plug 24 VDC 10%, Class 2, 2 A 24 VDC 10%, 8 A Power supply (for Control/Input) Power supply (for Output) 24 VDC +10/5%, Class 2, 2 A 24 VDC +10/5%, 8 A Enclosure IP67 (Manifold assembly) Standards CE marking, UL (CSA), RoHS recognition Weight 0.4 lbs (170 g) 0.4 lbs (175 g) EX600-ED3-l

Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system

10.7 17.2 12.6 13.5 12.1 19.9 12.5 20.1 31.1 18.5 20.4 31.2 45.3 23.6 27.4 42.6 41 42.9 6 4 5 20.6 13.6 Applicable tube 23.9 22.9 23.1 25.1 24.9 8 16.1 D 6 23.3 5 17.2 M A 10 17 L 8 39 24 27.7 8 46 d (Sealing face) 12 18.6 10 24.9 60 Connection thread 10 12 31.3 27.8 81 113 16 20.8 Note 1) D is maximum diameter.

psig (2.1 MPa) Vacuum to 3500 psig (24.1 MPa) 1) Source pressure 5000 psig (34.5 MPa) 10 psig (69 MPa) 40 to 160C (40 to 71C) (No freezing) 2) 0.09 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 3) 4 x 10-9 Pam3/sec 4) Ra 10 in. (0.25 m) Option: 25 in. (0.62 m) Face seal, Tube weld 0.38 pisg (0.0026 MPa) rise in delivery pressure per 100 psig (0.7 MPa) source pressure drop Bottom mount (Option: panel

25mm CCW CW 0 5 10 15 20 25 Stroke [mm] Origin 25mm CCW CW 10 15 20 25 30 35 Stroke [mm] Origin 25mm CCW CW -25 -20 -15 -10 -5 0 Stroke [mm] Origin 25mm CCW CW -15 -10 -5 0 5 10 Stroke [mm] Origin 25mm CCW CW -35 -30 -25 -20 -15 -10 Stroke [mm] 31 - Initial setting for the ORIG parameters Refer to the controllers (LEC series) operation manual for detail.

] 1000 32 32 25 25 1000 5 5 500 500 0 0 0 10 20 30 40 0 10 20 30 40 Circullating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR050-A/W-20-) 9.5.2 HRR050-A/W-402000 2000 Ambient temp Ambient temp 1500 1500 Heating capacity[W] Heating capacity[W] 40 40 32 32 25 25 1000 1000 5 5 500 500 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature