SMC Corporation of America
Elite Part Number Search
Search Results "RZQL50TN-100-20-M9BAVSAPCS"

Double acting, single rod, compact, water resistant cylinder ; Bore sizes (mm):  20, 25, 32, 40, 50, 63, 80, 100 ; Standard stroke range (mm):  5 to 100 ; Port threads: M (20 to 25 bore); Rc, NPT or G (32 to 100 bore) ; Auto switch capable

Double acting, single rod, compact, water resistant cylinder ; Bore sizes (mm):  20, 25, 32, 40, 50, 63, 80, 100 ; Standard stroke range (mm):  5 to 100 ; Port threads: M (20 to 25 bore); Rc, NPT or G (32 to 100 bore) ; Auto switch capable

VAC/DC Voltage 50 mA 40 mA 20 mA Max. operating current 30 G Impact resistance Operating Pressure Range Electrical Circuit ON pressure OFF pressure Up to 100 VAC/DC 0.5 Hysteresis Operating pressure (MPa) 0.4 Reed switch 0.3 0.2 0.1 0.1 0.2 0.3 0.4 0 Set pressure scale (MPa) How to Order IS1000 01 S Port size Seal Option 01 N01 X201 R 1/8 NPT 1/8 None With seal Lead wire length 3 m Regulating

Specifications Port Size (Applicable Tubing O.D.): ø1/8" / ø5/32", Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 50 / 80, Flow Rate (Vacuum Pressure) [L/min]: 7 / 10, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2

Specifications Port Size (Applicable Tubing O.D.): ø1/8" / ø5/32", Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 50 / 80, Flow Rate (Vacuum Pressure) [L/min]: 7 / 10, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2

Specifications Port Size (Applicable Tubing O.D.): ø1/8" / ø5/32", Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 50 / 80, Flow Rate (Vacuum Pressure) [L/min]: 7 / 10, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2

Specifications Port Size (Applicable Tubing O.D.): ø1/8" / ø5/32", Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 50 / 80, Flow Rate (Vacuum Pressure) [L/min]: 7 / 10, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2

20 4 10.4 26.8 17 33 33 36 17.7 6 12.8 26.8 18.5 33 36 33 40.3 35.3 R 1/4 17 18.5 34.8 29.4 (18.2) 8 15.2 29.4 20.5 35 35 38.6 (40.8) (35.8) 10 18.5 37.3 23 38 38 46.5 18.3 (18.8) 6 12.8 29.4 18.5 59 40.9 55 8 15.2 31.9 20.5 61 43.4 57 19.8 45.8 40.8 R 3/8 19 23 40.6 35.6 10 18.5 33.6 45.1 23 63 59 (20.9) (46.9) (41.9) 12 20.9 34.8 46.3 24 65 61 10 18.5 35.6 49.9 23 107 100 24.5 57.2 49.7

20 4 10.4 26.8 17 33 33 36 17.7 6 12.8 26.8 18.5 33 36 33 40.3 35.3 R 1/4 17 18.5 34.8 29.4 (18.2) 8 15.2 29.4 20.5 35 35 38.6 (40.8) (35.8) 10 18.5 37.3 23 38 38 46.5 18.3 (18.8) 6 12.8 29.4 18.5 59 40.9 55 8 15.2 31.9 20.5 61 43.4 57 19.8 45.8 40.8 R 3/8 19 23 40.6 35.6 10 18.5 33.6 45.1 23 63 59 (20.9) (46.9) (41.9) 12 20.9 34.8 46.3 24 65 61 10 18.5 35.6 49.9 23 107 100 24.5 57.2 49.7

SUP (SUP air) IN (SIG air) qInput chamber uDiaphragm A iDiaphragm B oSpool wFeedback spring EX OUT2 EX OUT1 eInput diaphragm yNozzle rConnecting rod tCylinder rod 152 Cylinder Positioner IP200 Series Dimensions 20 20 25 SIG OUT1 OUT2 20 25 2 x 6.6 OUT1 OUT2 IN side Rc1/4 38 60 50 SUP 31 35 135 + Stroke IP IP IW 97 1301 40 SUP AW 37 Rc1/4 M8 x 1.25 depth 15 IL1 66 62 + Stroke 80 IL2 Precautions

10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?