5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?
5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?
5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?
5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?
5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?
5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?
p10%50 mA or lessIP650 to 50C (with no freezing and condensation)Operation, Storage: 35 to 85% R.H.
output, switch output off Switch output (During SIO mode) Switch operation Normal output, reversed output Maximum load current 80 mA Maximum applied voltage 30 V (during NPN output) Internal voltage drop (Residual voltage) 1.5 V or less (Load current 80 mA) Delay time 1 1.5 ms or less, Variable at 0 to 60 s/0.01 s step Hysteresis Hysteresis mode Variable from 0 2 Window comparator mode Short
or less Switch output NPN PNP NPN PNP open collector open collector open collector open collector Max. load current 80 mA Max. applied voltage 30 V (NPN output) Residual voltage 1.5 V or less (80 mA load current) Output protection Short Circuit Protection 0.01 mm or less 0.01 mm or less Repeatability (including temp. characteristics) (Detection distance range (Detection distance range 0.01
or less Switch output 1 output (NPN or PNP) Maximum load current 10 mA Maximum applied voltage 26.4 V Residual voltage 1 V or less (at 10 mA) Short circuit protection Provided Repeatability 0.005 mm 0.010 mm 0.020 mm Temperature characteristics (Reference: 25C) 0.010 mm 0.015 mm 0.030 mm Hysteresis 0 to variable (Default: 3) 0 to variable (Default: 20) Display 2-screen display, LCD Main
ON voltage 11 to 30 V OFF voltage 3 to 5 V Internal current consumption 50 mA or less Weight 280 g 1 An M12 (4-pin) connector can also be connected.
Maximum allowable load current is 80 mA. Be sure to not exceed 80 mA. 1. Mounting orientation is available either horizontally or vertically. 2. Be sure to hold the main body when handling. 3. Do not drop or strike body. Excessive impact may damage the switch inside. 4. During installation or removal of the sensor, use a wrench on the Hex.width across flats for PT threads.
Maximum allowable load current is 80 mA. Be sure to not exceed 80 mA. 1. Mounting orientation is available either horizontally or vertically. 2. Be sure to hold the main body when handling. 3. Do not drop or strike body. Excessive impact may damage the switch inside. 4. During installation or removal of the sensor, use a wrench on the Hex.width across flats for PT threads.
Note 7) Purchase an earth leakage breaker with current sensitivity of 15 mA or 30 mA/power supply 100 VAC separately. Note 8) Dimensions between panels, not including the dimensions of protrusion. Note 9) Weight in the dry state without circulating fluids.
(Do not use this product with continuous voltage fluctuations.) *1 Select an earth leakage breaker with a leak current sensitivity of 30 mA. Regarding the rated current, refer to the Applicable Earth Leakage Breaker Capacity.
Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator
IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part
Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection 32 to 100 20, 25 B B D-M9 D-M9W D-M9A D-A9 D-M9 D-M9W D-M9A D-A9 D-Y5 D-Y7 D-Y7W D-Y7BA D-Z7 D-Z80 A B MA B MA A D-M9V D-M9WV D-M9AV D-Y6 D-Y7V D-Y7WV D-A9V D-M9V D-M9WV D-M9AV D-A9V A A Auto Switch Proper Mounting Positions (mm) Solid state auto switch Reed auto switch D-Y59/Y69 D-Y7/Y7V D-Y7W/Y7WV D-Y7BA
100 mA Response frequency 30 Hz 25 Hz Housing material PBT PA6, PBT Clamping side: Red Clamping side: Red Output indication Unclamping side: Yellow Unclamping side: Yellow Voltage indication Green Green Note) Switch specifications are corresponding to manufacturers technical information.
D-A93 D-M9B D-M9N, D-M9P Type Load voltage Load current range Indicator light Application Reed auto switch Solid state auto switch 24 VDC, 100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 40 mA, 5 to 20 mA 2.5 to 40 mA 40 mA or less Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors