model SF4 DZ 1 21 Coil rated voltage Manual override Individual pilot exhaust Electrical entry, Light/Surge voltage suppressor For VFS120 21 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC (50/60 Hz) 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Option Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Locking
Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.
A96V A96 IC circuit 5 V Yes A72 A72H Grommet Reed switch 12 V 200 V 100 V A93V A90V A93 A90 IC circuit 5 V,12 V 12 V 100 V or less No Relay, PLC 2-wire 24 V A73C A80C A79W Yes No Connector IC circuit 5 V,12 V 24 V or less Grommet Yes With diagnostic output (2-color indication) Solid state auto switches marked with a "" are produced upon receipt of order.
The maximum speed will be 141 mm/s. 50 32 25 20 10 5 16 Load mass (kg) 10 (2.5) 6 [Double acting (D), Single acting, Spring return (S)] 6 [Single acting, Spring extend (T)] 1 0.5 0.1 0.05 0.01 50 100 300 200 (141) 500 Maximum speed (mm/s) 2. Rod end allowable lateral load Make sure that the lateral load that is applied to the rod end will be no more than the values shown in the tables.
Fitting marking for applicable tubing material Connection Tubing Barb fittings Barb elbow Barb elbow (H) Soft nylon tubing Polyurethane tubing Made to Order (Refer to page 200 for details.)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BJ (B + J)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BM (B + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)