Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 32 lb
10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., VACUUM SWITCH, VACUUM SERIES, ZSE20, CB, ZSE20 1/8 INCH NPT VERSION
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N63, "VACUUM SWITCH
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -
Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -
Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -
Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None, Lead Wire: None, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: -, Calibration Certificate: -, Series
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m)