The power supply voltage between the power supply terminal PWR_24V and PWR_GND is outside of DC24 V +/10%. Power supply Use a power supply voltage of DC24 V+/-10%. PWR LED: error PWR signal: 1 Green flashing Continue OFF (Outside of 24 (Cycle: 1 Hz) V+/-10%) The power supply voltage between the power supply terminal PWR_24V and PWR_GND is below 17 V.
indication (2-color indicator) 2-wire 3-wire (PNP) 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V,12 V 3-wire IC circuit E76A 5 V (NPN equivalent) Yes Grommet E73A E80A 24 V 12 V 5 V,12 V 100 V 2-wire Relay, PLC IC circuit N0 100 V or less Lead wire length symbols: 0.5 mNil (Example) M5BW 3 m L (Example) M5BWL 5 m Z (Example) M5BWZ Solid state auto switches marked with are produced
www.stevenengineering.com I 5.23 AIR PREPARATION SERIES NAP100 PRESSURE CONTROL VALVE The (N)AP Series pressure relief regulator is an adjustable re l i e f v a l v e w i t h a c o n t ro l r a n g e o f 1 8 ~ 1 0 0 P S I .
110 VAC [115 VAC] VFN 220 VAC [230 VAC] Electrical entry Manual override 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC Grommet L plug connector M plug connector Nil: Non-locking push type D: Push-turn locking slotted type G: 300 mm lead wire L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire L P B: Locking slotted type E: Push-turn locking
For DC voltages other than 12 V and 24 V, incorrect wiring will case damage to the surge suppressor circuit. Applied voltage 24 V 0 V Standard With power saving circuit 0.4 W 0.1 W 0 W 62 ms 1-5-76 77 Series SYJ3000/5000/7000 Specific Product Precautions 4 Be sure to read before handling.
M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .
o o o I v o Turpentine o o o o V o tr Urea o o o I o o Water o D o o o o o o Zinc Chloride a o V V o o o Zinc Sultate V o o o o I Y 26 World Wide QS\E Support...
110 VAC [115 VAC] VFN 220 VAC [230 VAC] Electrical entry Manual override 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC Grommet L plug connector M plug connector Nil: Non-locking push type D: Push-turn locking slotted type G: 300 mm lead wire L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire L P B: Locking slotted type E: Push-turn locking
Heavy-duty cord 3-wire (PNP) 12 V MDSUA1 Relay, Grommet 24 V 5 V, 12 V 5 V, 12 V, 24 V MDSUA3 Parallel cord IC circuit PLC 2-wire 5 V, 12 V, 100 V 5 V, 12 V, 24 V, 100 V Heavy-duty cord Reed switch Parallel cord 100 V Heavy-duty cord 3-wire (NPN) 5 V, 12 V IC circuit Solid state switch Grommet 3-wire (PNP) 12 V MDSUA7 Relay, Connector Grommet Connector Grommet Connector Heavy-duty cord 2
ALARM is expressed as negative-logic circuit. (2) Positioning Operation (4) Stop by the STOP Signal 24 V 0 V 24 V 0 V Power supply Power supply ON OFF ON OFF IN0-3 IN0-3 Input Input ON OFF OUT0-3 STOP Output ON OFF BUSY OUT0-3 Release Hold BUSY External lock Output ALARM 0 mm/s Speed Positioning operation Release Hold External lock OUT0-3 output signals are ON in the same state as the input
DC Auto switch model Lead wire length (m) Electrical entry Wiring (Output) Load voltage Indicator light Pre-wired connector 3 (L) 5 (Z) Applicable load 0.5 (Nil) Type F6N 3-wire (NPN) 5 V 12 V IC circuit Yes Grommet Solid state switch Relay, PLC F6P 24 V 3-wire (PNP) F6B 12 V 2-wire Auto switches marked with a symbol are produced upon receipt of orders.
4 Exhaust port 76 P Standard ZL212 40 V ZA 54 125 Label ZX 188 61 ZR P Port exhaust ZL212P ZM V ZMA Exhaust port (EXH.)
/-R () NPN 2 Max.28 V80 mA 1 V -21No.PS-OMU0005CN-C -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -Y () -V/-T () PNP 2 Max.28 V80 mA 1 V -22No.PS-OMU0005CN-C [] 3 0.2 [] / OUT2 OUT2 OUT1 OUT1 [F10]30 () 13 35 1 (62 ) () () (27 ) (29 ) (3 ) (25 ) 3 () 3 -23No.PS-OMU0005CN-C ON OFF ON ON OFF ISE20B [P_1] OUT1 0.500
is not supplied: Goes off Power supply connector 24 V DIA 1 DIA error: Lights up Normal DIA: Goes off Power supply for output 0 V PWR (V) BF PROFIBUS DP communication error: Lights up Normal PROFIBUS DP communication: Goes off Power supply for input and controlling GW COM A COM A is receiving data: Lights up 2 COM A is having no data to receive: Goes off PWR 0 V 24 V COM B COM B is receiving
(Brown) +24 V TD+ TD0 V INPUT OUTPUT DA DB DG SLD FG COM A Pressure welding for branch connector The method of pressure welding for branch connector is explained. (1)Components Internal circuit +24 V RD+ RD0 V FG Insulating cap Brown Black White Blue DC-DC converter (Insulation) Pin no. display Power supply for output +24 V TD+ TD0 V +24 V 0 V INPUT OUTPUT COM D Power supply for input and
5 V, 12 V 100 V 100 V or less IC circuit IC circuit Relay, PLC Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 3-wire Reed switch Solid state switch Yes Grommet 24 V 2-wire No 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit BMP1-032 12 V Relay, PLC 24 V Grommet Yes Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Water resistant (2-color
5 V, 12 V 100 V 100 V or less Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV IC circuit IC circuit Relay, PLC 3-wire Reed switch Solid state switch Yes Grommet 24 V 2-wire No 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit BMP1-032 12 V Relay, PLC 24 V Grommet Yes Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Water resistant (2-color
Hardware failure) 1 24 V (Output) 1 24 V (Output) HUNGARY (36) 23 513 000 OFF PROFINET communication is established. 2 0 V (Output) 2 0 V (Output) Torbgy u. 15-19, 2045 Trkblint, Hungary 3 2 PROFINETcontroller settings and EX600 configuration data do not match. 24 V (Control and input) 24 V (Control and input) 1 2 Red LED flashes. 3 3 4 5 4 1 Red LED is ON.
For example, when analogue output is 1 to 5 V, F.S.=5[V] 1[V]=4[V]. (Reference: 1%F.S. = 4[V] 1% = 0.04[V]) F F.S. (full span / full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering.
110 VAC [115 VAC] VFN 220 VAC [230 VAC] Electrical entry Manual override 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC Grommet L plug connector M plug connector Nil: Non-locking push type D: Push-turn locking slotted type G: 300 mm lead wire L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire L P B: Locking slotted type E: Push-turn locking