Piping port (IN side) 11/4 54 mm Measurement mode Bracket (Option) 11/2 54 mm *: Green: Flashes once. PF3W5 -1 (Analogue 1 to 5 V type: Without temperature sensor) Flashes twice. PF3W5 -2 (Analogue 4 to 20 mA type: Without temperature sensor) Flashes three times. PF3W5 -1T (Analogue 1 to 5 V type: With temperature sensor) Tighten to the specified torque for piping.
Otherwise it can cause failure or malfunction of the system. 11/4 54 mm Temperature upper limit exceeded Flow range, unit specification and mounting of temperature sensor are displayed Set value Sets the ON or OFF point of the switch output. 50 oC 11/2 54 mm The fluid temperature is above 110 oC. Reduce the fluid temperature.
(Ensure there is no fiber or dust in the groove.) 12 XL-OMM0005-A Replacement procedure Division 1 Model High Vacuum Angle Valve Step 7 Step 8 Step 9 Step 10 Step 11 Screw for fixing valve S assembly Valve S seal assembly (mount it after checking it has one O-ring.)
Fault No.11 Problem Possible cause Investigation method Countermeasures The inputs that are beyond the maximum point number do not operate. Check that the number of inputs has not exceeded the allowable number. The allowable number depends on the SI unit model. Inadequate total number of inputs from the Input block connected with the SI unit.
If the minimum setting unit is 1 L/min, the flow can be displayed in 1 L/min units, i.e. 10, 11, 12. Minimum setting unit N Normal condition (NOR) Reference condition for volumetric flow: 101.3 kPa, 0 C The flow measurement which is converted at normal atmospheric pressure conditions at 0 C.
No.PS-OMM0003-J PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ZSE80(F) ISE80(H) Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Installation 14 Piping 16 Wiring 17 Pressure Setting 19 Measurement mode 19 Function Setting 21 Function selection mode 21 Default
. / (420) 5-414 24611 NORWAY / (47) 67 12 90 20 DENMARK / (45) 70 25 29 00 POLAND / (48) 22-548 50 85 FINLAND / (358) 9-859 580 PORTUGAL / (351) 2 610 89 22 FRANCE / (33) 1-64 76 1000 SPAIN / (34) 945-18 4100 GERMANY / (49) 6103 4020 SWEDEN / (46) 8-603 0700 GREECE / (30) 1342 6076 SWITZERLAND / (41) 52-396 3131 HUNGARY / (36) 1-371 1343 TURKEY / (90) 212 221 1512 IRELAND / (353) 1-403 9000
Load (N) Torque (Nm) Stroke 50 75 100 125 150 175 200 Stroke 50 75 100 125 150 175 200 L L 42 2.87 m m 42 2.47 40 2.17 42 2.38 32 2.16 24 1.98 17 1.82 50 to 200mm stroke F T 10 Load weight m (kg) F 125 to 200mm stroke Plate non-rotating accuracy () 50 to 100mm stroke Non-rotating accuracy () 0.09 1 + 0.1 10 50 100 Eccentric distance L (mm) Refer to page 304 for deflection data. 24 248 41
Series AS-FG Speed Controller with One-touch Fittin Stainless Series. 5 5 6 7 9 11 11 11 11 12 13 13 13 15 15 16 16 16 17 17 18 19 21 22 22 23 24 25 27 27 27 29 30 31 31 31 32 34 35 35 35 36 36 37 37 37 38 38 39 39 39 41 42 43 43 43 44 45 46 46 Specifications. How to Order . Construction. Dimensions . Series AS-FG Speed Controller with One-touch Fittings Stainless Series In-line Type.
(s P. 11 ) (2) The weight of a transferred object and transfer speed should be within the allowable range as shown in the graphs. (3) Overhang L3 should be 30 mm or less. V m L3 30 mm Caution (1) If a load is applied in the direction as shown on the right side, an eccentric load will be applied to the guide.
Check that the internal tank has no leakage if using an external tank. 11. If there is a point where fluid is released to atmosphere externally (tank or piping), minimize the piping resistance at the circulating fluid return side.
Refer to LECYU Operation Manual,section 3.3.1. and 3.3.2. 11 - 2.3.1 I/O Signal (CN1) Names and Functions The following table shows the names and functions of I/O signals (CN1). (1) Input Signals Signal Pin No.
NO.ZL3-OM00701-A PRODUCT NAME Digital pressure switch for energy-saving control ejector MODEL / Series / Product Number ZSE10ZL3ZL6 series Table of Contents Safety Instructions 2 How to order read wires 9 Summary of Product parts 10 Definition and terminology 11 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Easy Setting 17 Measurement mode 17 Function Setting 20 Function selection
(page 41, "3,"). 2, After the security code is entered and the indication changes to [UnL], Press and hold the and buttons simultaneously for 5 seconds or longer. [000] is displayed and the new security code should be entered. For how to input the security code, refer to "How to input and change the security code".
10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 27 30 31 37 40 1/4 3/8 3/8 1/2 1/2 84 90 98 116 126 146 159 170 204 215 16
Note) N.C. and N.O. common Differential pressure indication switch Note) 41 Flange Element Construction 42 only Relief valve Hydraulic fluid Indicates 42 for 3.5 MPa, Port sizes 3/4 and 1.
/4" x 11/10" 11/4" 31.75 11/10" 27.95 KQB2 O.D. 3.18 1/16" 1.58 0.086" 2.18 KS KX I.D.
VPA3185 118 13 2 132 14 80 95 140 52 140 41 81 105 2 1575