60 74 26.5 30 37 121.5 138 161 20 24 24 130.5 148 171 8 10 12 55 63 74 Port size/Flange: 32F, 40F, 50F J (Valve open) Indicator (Option) Pilot port E 12(P1), 10(P2) Port size: refer to table below P1 P2 H H D B A 32 B C G F 4 x 2 x 18 mounting hole A Applicable flange 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H J Model VND50D-32F VND60D-40F VND70D-50F 8 10 12 50 40 32 1 8 1 4 1
at the time of shipment Connector for pressure sensor controller + Sensor cable ZS-26-J Definition and terminology Terms Meaning F Abbreviation for full span and full scale; means the maximum fluctuation range of the Pressure switch rated value.
Example) AW30K-03BE-1N-B B AW 30 03 BE K q w e r t y q Body size 20 30 40 60 Symbol Description w With backflow function Nil Without backflow function K Note 1) With backflow function + e Pipe thread type Nil Rc N Note 2) NPT F Note 3) G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 r Port size 10 1 + a Mounting Nil Without mounting option B Note 5) With bracket H With set nut (for panel mount
q NC G RA1B with Auto swllch cap"ou,O J T With Auto Swllch Capsbiliry J | | D-withbuin-inmasner J I &-*"-l See above Bor See above ,f The stsrda|d liead wire length is 18 inches. "L' is addecl for 10loot long lead wire.
(Variable) 3% F .S. or less (Fixed) 1 to 10% of set prss.
Example)AC30-F03DM-KSTV-13NR-A q r t y w e q Symbol Bodysize Description 20 25 30 40 Rc NPT G Nil N F Threadtype w + 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 Portsize e + Floattype autodrain a Withoutautodrain N.C.(Normalclose)Drainportisclosedwhenpressureisnotapplied. N.O.(Normalopen)Drainportisopenwhenpressureisnotapplied.
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
T 25 TF L CKZP 57 TF T 25 CKZP 71 Switch output display Bore size Retracted Extended Nil Yellow Red 71 71 mm R Red Yellow Port thread types TF G TN NPT Proximity switch T TURCK P P&F Stroke 25 25 mm 50 50 mm Proximity Switch Specications Specications Bore size 57 71 Manufacturer TURCK P&F Power supply voltage 10 to 30 VDC 10 to 30 VDC Fluid Air Output N.O., PNP N.O., PNP Maximum operating
200 to 230 VAC (60 Hz) Allowable voltage range 10% (No continuous voltage uctuation) Applicable earth Note 8) leakage breaker Rated current A 30 20 Sensitivity of leak current mA 30 Rated operating current Note 5) A 15 8 Rated power consumption Note 5) kW (kVA) 4.6 (5.2) 5.0 (5.6) Noise level (Front 1 m/Height 1 m) Note 5) dB (A) 66 Accessories Alarm code list stickers 2 pcs.
N.C 3 N.O 1 2 7 6 5 4 N.O PE L N TB PLC GFCI ILS M C TC M C PLC THS M C OLR PTC CM PLC PTC C01 CM IDH6-10 TC IDH6 / IDHA6 TS M C F H SSR FM PRS P FM 1 IDH6/IDHA6 IDH6 / IDHA6 IDH6/IDHA6 IDH6 / IDHA6 CM FM OLR PRS ILS PTC PTC() MC THS TB TC TS SSR H F GFCI PLC 64 IDH Series IDX-OM-W038 . 6.4 6.3 IDH6 / IDHA6 1 65 IDH Series 6.4 IDX-OM-W038 7 7 7-1 / IDH Series 7-17-
Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10
Floating Joint JC Series Light Weight Type for Light Load 20, 30, 40, 63 RoHS Light weight Light weight Aluminum case 30% reduction Compared to the current model JA40 With the aluminum case J J Weight 48 g lighter 112 g 160 g JA40 JC40 Product suitable for air cylinders Light weight mitigates lateral loads to air cylinders.
L1 L2 L3 L4 L5 L6 L7 (1) L8 D Model Bore size ASV AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 5 17 54.5 16 15.5 50 30 10 4.5 AK 1 4 1 4 2 x M4 x 0.7 11.5 17 56 51.5 40 5 23 20 30 4.5 Effective thread depth 6 Reference dimensions 8 3 45.5 5.25 20.6 61 13.2 68 56 25 26 5.5 VCHC Note 1) L7: Reference dimensions Dimensions: AS5000 ASR ASQ 2 x 1/4 to 1/2 2-1/4 to 1/2 74.9 (Max. 82.9)
Model *1 Port size A B D E300-03-A 3/8 31.8 30 30 E400-04-A 1/2 31.8 36 36 Port size B *1 in model numbers indicates a pipe thread type. No indication is necessary for Rc; however, indicate N for NPT, and F for G. * Separate spacers are required for modular units.
Rubber back of the belt is softened and sticky. f. Crack on the back of the belt 4. Troubleshooting Alarms below are abstract of representative examples.
Start flag 0: no send Numerical data input 2 1: send 1 Step data No 0 to 63 Data writting 3 Operation Note) 1 1: Absolute 2: Relative 4 H 5 L Speed 2 0 to 65500 mm/s 6 3 7 2 Position 4 +/-2147483647 0.01mm 8 1 9 0 ID1 Numerical 10 H 11 L Acceleration 2 0 to 65500 mm/s2 data input 12 H 13 L Deceleration 2 0 to 65500 mm/s2 Data writting 14 Pushing force 1 0 to 30 10% 15 Trigger LV 1 0 to 30
Confirmation of allowable load weight by application Vertical upward: Lifter Vertical downward: Press Horizontal: Chucking L l m m F m F Maximum speed mm/s (in/s) Maximum speed mm/s (in/s) Load center of gravity position l mm (in) to 300 (11.8) to 500 (19.7) to 700 (27.6) to 300 (11.8) to 500 (19.7) to 100 (3.9) to 200 (7.9) to 300 (11.8) Graph Graph Graph Graph Graph Graph Graph Graph l
L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover
0.3 m lead wire LZ L plug connector, with 0.3 m lead wire, with light/surge voltage suppressor LN L plug connector, without lead wire (applicable to DC) LO L plug connector, without connector Standard supply pressure H M 0.5 MPa 0.35 MPa (Except nozzle diameter 05 type) Thread type Rated voltage Nil T NPTF Rc 1 3 100 VAC 50/60 Hz 110 VAC 50/60 Hz 5 24 VDC 6 12 VDC V 6 VDC S 5 VDC R 3 VDC F