AC DC Auto switch model Lead wire length (m) Load voltage Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line 3-wire Reed switch Solid state switch A96V A96 5 V IC circuit Grommet (NPN equivalent) Yes Yes Relay, PLC 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV
A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002 10. 10-1. 2 2P5P6 16 XL-OMY0002
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) When 2 auto-switches are specified they are assembled for shipping.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.
Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ Since there are other applicable auto switches than listed, refer to page 8-7-22 for details.
NPN) Yes 5V A96 A96V IC NCQS-L012 NCQS-L016 NCQS-L020 NCQS-L025 NCQS-F012 NCQS-F016 NCQS-F020 NCQS-F025 NCQS-D012 NCQS-D016 NCQS-D020 NCQS-D025 12 16 20 25 3 wire (NPN) M9N F9NV Note 1) 2 pieces per cylinder should be ordered. Each package contains the following parts.
1122Series MXP/MXPJ6 Air slide table 6, 10, 12, 16 How to Order Clean series 11 Vacuum suction type MXP 11 12 15 M9N MXP 22 12 15 M9N Copper, fluorine and silicon-free + low particle generation Number of auto switches Nil s n 2 pcs. 1 pc. n pcs. 22 Vacuum suction type Bore size Stroke mm Type of auto switch 6 10 12 16 5, 10 10, 20 15, 25 20, 30 Nil Without auto switch Refer to the table
63 63 3000 40 50 2000 500 50 1000 40 0 0 5 10 15 20 0 450 400 350 300 250 200 150 100 50 0 Arm length L (mm) Arm length L (in) Allowable load for clamp arm end Refer to the graph on pages 190 and 191 for parts weight of the arm.
Assuming that the tube I.D. is 2 mm, the piping capacity is as follows: V = /4 x D2 x L x 1/1000 = /4 x 22 x 1 x 1/1000 = 0.0031 L (2) Assuming that leakage (QL) during adsorption is 0, find the average suction flow rate to meet the adsorption response time using the formula on the front matter 17.
R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult SMC Customer Service for larger sizes.
Cushioning nearly equal to a shock absorber is achieved with a unique cushion ring configuration and cushion seal design. 3.5 80 25 to 1300 25 to 1000 25 to 1500 100 50 to 1000 50 to 1300 125 50 to 1200 50 to 1500 160 CHAW CHA Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
/2000 1000/5000 500/2000 200/1000 100/500 100/200 *Dimension A reference after installation.
How to Order AL800 AL 23 80 12 0 R AL900 Semi-standard R Flow direction: Right Left Body size Port size Semi-standard Lubricator 1 1S-1 1S-2 2 3 6 8 1000 cm3 tank 1000 cm3 tank with switch (Bottom limit ON) 1000 cm3 tank with switch (Bottom limit OFF) Metal bowl With drain cock Nylon bowl (Including sight dome) Metal bowl with level gauge Symbol 12 14 20 4 1 1 1 2 2 1 80 90 1 2 2 1 Thread
Operating Parameters Status Gas Operating pressure Proof pressure Burst pressure Ambient and operating temperature Cv Vacuum to 250 psig (1.7 MPa) Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 14 to 160F (10 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in
Value (-32767.. 32767 ) Value x 0.01 (mA or V) 1000 8 Upper Limit Value*1 1: True Generates an error. *1 9 Monitor Lower Limit 0: False Does not generate an error. Generates error per channel when the input value falls below the set value.
) [P_1] OUT1 [ 500] 500 L/min(PFMB7102) [F 1][oU1] [1000] 1000 L/min(PFMB7202) 28 [ 25] 25 L/min(PFMB7501) [H_1] OUT1 [ 50] 50 L/min(PFMB7102) [100] 100 L/min(PFMB7202) [CoL] OUT1 [SoG] ONOFF [oU2] OUT2 2 [HYS] [2ot] OUT2 2 [2_P] [ 250] 250 L/min(PFMB7501) 2 [P_2] OUT2 [ 500] 500 L/min(PFMB7102) [F 2][oU2] 36 [1000] 1000 L/min(PFMB7202) [ 25] 25 L/min(PFMB7501) 2 [H_2] OUT2 [ 50] 50 L/min
1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig. 9-4 Cooling capacity(HRS050--20-(BJM)) 9.5 Heating capacity 9.5.1 HRS050-A-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 1500 1500 5 Heating capacity [W] Heating capacity [W] 5 20 20 25 25 1000 32 1000 32 40 40 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15
HRS060-A-2060Hz 9.5.1 HRS060-A-20-(BJM) 2000 2000 Ambient Ambient temperatur temperatur Heating capacityW Heating capacityW 1500 1500 e e 40 40 32 32 1000 1000 25 25 20 20 5 500 5 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature Circulating fluid temperature 60Hz 50Hz Fig. 9-5 Heating capacity(HRS060-A-20-(BJM)) 9.5.2 HRS060-W-20-(BJM) 2000 2000 Ambient
Max. 2s 2s 1s 1s Min. 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.05s 0.02s 0.02s 0.01s 0.01s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 100 125 200 300 400 500 600700 1000 1500 2000 3000 4000 600 5000 7000 Current (% for breaker capacity) Current (% for breaker capacity) For HRS100-A/W-20-B For HRS150-A/W-20-B HRS100-A/W-40, HRS150-A/W-40 4h 2h 1h 30min 20min 14min 10min 6min
Monitoring of TEMP READY alarm (AL12) does not start since Start Time is set at 1000 sec. Status (6): Monitoring of TEMP READY alarm (AL12) starts at this point where 1000 sec of Start Time has elapsed. Status (7): TEMP READY signal output continues since the temperature is now back within the Out Time range of 200 sec even though it was temporarily outside the Low range.