Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: None, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: High-pressure w/Power Saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1/4-28UNF, PVDF, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: 3 Port, Universal, Function: High-pressure w/Power Saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1/4-28UNF, PVDF, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Standard w/Power Saving Circuit, Voltage: 12VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1/4-28UNF, PVDF, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted Type,
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted Type,
Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted Type,
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance.
Please contact us for the latest version.sales@ocaire.com, VALVE, VALVE, LVM110 CHEMICAL VALVE, 3-PORT, 2C, LVM110 BODY PORT, NO SIZE RATE, 0.09799 lb, ModelValve constructionValve typeNumber of portsFluid Note 1)Operating pressure rangeOrifice diameterResponse timeLeakageProof pressure Note 2)Ambient temperatureFluid temperatureVolume of valve chamberMounting orientationEnclosureWeightRated
Please contact us for the latest version.sales@ocaire.com, VALVE, CHEMICAL, BASE MOUNTED, VALVE, LVM110 CHEMICAL VALVE, 3-PORT, 2I, LVM 3-PORT, NO SIZE RATING, .00000 lb, ModelValve constructionValve typeNumber of portsFluid Note 1)Operating pressure rangeOrifice diameterResponse timeLeakageProof pressure Note 2)Ambient temperatureFluid temperatureVolume of valve chamberMounting orientationEnclosureWeightRated
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance.
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance.
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance.
Symbol: 10R6 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 3 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 1 (Bracket), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 1 (Bracket), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 1 (Bracket), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: None, Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 1 (Bracket), Lead Wire Length: 10 (1000mm)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1U (PVDF, 1/4-28UNF), Option: 1 (Bracket), Lead Wire Length: 6 (600mm)