Flow Direction Symbols on Body How to Order Meter-out type Meter-in type Indication symbol 2 1 01 06 2 AS 1 F E S K Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Symbol Applicable tubing O.D.
Series AM, AMD, AMH, AMG 150 CA AM AMD AMH AMG Thread type (3) Nil Rc F G N NPT Body size Accessory (Option) A With drain cock (1) Note 3) Corresponds to attachment symbols C, D, and J. Select according to the type of threads used on the body. C With N.O. auto-drain D With drain guide (2) 150 250 350 450 550 650 850 With N.C. auto-drain J Note 1) 850 size comes with a ball valve.
C A D Model D C Model D C Mounting bolt (mm) Mounting bolt (mm) M18 x 125 l M18 x 135 l 125 135 C (D) Q2B18010DC C (D) Q2B20010DC M18 x 135 l M18 x 145 l 135 145 C (D) Q2B18020DC C (D) Q2B20020DC M18 x 145 l M18 x 155 l 145 155 C (D) Q2B18030DC C (D) Q2B20030DC M18 x 155 l M18 x 165 l 36 155 39 165 C (D) Q2B18040DC C (D) Q2B20040DC M18 x 165 l M18 x 175 l 165 175 C (D) Q2B18050DC C (D) Q2B20050DC
Coil voltage 1 2 3 4 5 6 9 100VAC(50/60Hz) 200VAC(50/60Hz) 110VAC(50/60Hz) 220VAC(50/60Hz) 24VDC 12VDC Others 13 Series VQZ How To Order Manifold Connector Kit Preferred Option Program How To Order: VQZ100 Base Mounted Manifold VV3QZ 1 5 08 N7T C Option Series None DIN rail mounting (DIN rail standard length) External pilot 1 VQZ100 D R Manifold type 5 Base mounted Kit C Connector Number
(Parameter initial configuration Set the recommended parameter value Operation start) *3 The travel distance of the actuator per 1 pulse should be 10 [m/pulse]. 26 - Recommended Parameter Values [LEY] LEY25/ LEY25D/ LEY32/ LEY32D/ LEYG25 LEYG25D LEYG32 LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para.
A B C D Switch Internal Circuit Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.
Tension bolt Table 3 Guideline of the wing nut tightening amount Model FGES L A FGES L B FGES L C Element size (mm) 65 to 70 250 65 to 70 500 65 to 70 250 65 to 70 750 65 to 70 250 Wing nut tightening amount 26 to 30 40 to 45 33 to 38 51 to 55 27 to 44 Wing nut tightening amount (mm) 11/12 FGX-OM-L008-A 5-4 [Mount O-ring and cover] (1) Set O-ring to the case (2) Rotate the cover clockwise
glycol 1, 4-dioxane 49.5 (43) Ether MTBE TAME INLET OUTLET Pyridine Amine Butyl amine Fuel C: Methanol = 75/25 Gasohol Fuel C: Methanol = 50/50 Fuel C: Methanol = 25/75 Consult SMC for fluids other than those listed. 6 Series FQ1 Made to Order Consult SMC for detailed dimensions, specifications and lead times. 4 Nonstandard Elements for Precision Cleaning -X0 X0 FQ101 Option Element size
Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the
N.O. 0.4 0.3 0.2 0.1 0.2 0.3 0.4 0.5 0.6 Operating pressure (MPa) Flow Characteristics/Weight C [dm 3/(s bar)] b Cv C [dm 3/(s bar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Flow characteristics Weight (g) Effective area (mm2) Pilot port size Type of actuation Port size SYJA312-M3 SYJA322-M3 SYJA314-M5 0.41 0.18 0.086 0.35 0.33 0.086 Body ported N.C. N.O. N.C.
/s) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80 1400 C95 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175
Two mounting styles Table traveling accuracy C D Bottom mount Top mount Model Traveling accuracy C side against A side D side against B side LG1H 0.1 or less 0.1 or less A B Variations Mounting orientation Lead screw type Motor type Guide type Motor/Screw connection Series Standard motor [Tamagawa Seiki Co., Ltd.]
, 320, 400, 500 2000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 2000 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 Intermediate strokes are available
(1) 5 to 55 Ambient temperature (C) 5 to 50 5 to 55 5 to 50 VC Outlet air atmospheric pressure dew point (C) 20 VDW Inlet air flow rate l/min (ANR) (2) 625 62 125 250 375 VQ Outlet air flow rate l/min (ANR) 50 100 200 300 500 VX2 Purge air flow rate l/min (ANR) (3) 12 25 50 75 125 VX Inlet air pressure (MPa) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080
Key-lock function 4 OUT1 (C/Q) Hysteresis H_1 Flow [L/min] Safety Instructions 5% of maximum rated flow [00.20] 0.20 L/min (4 L type) [000.8] 00.8 L/min (16 L type) [002.0] 02.0 L/min (40 L type) [00.05] 0.05 L/min (100 L type) [00.12] 0.12 L/min (250 L type) The self tapping screws should not be re-used. Self tapping screws (4 pcs.)
A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Point table No.1 Initial value Recommended value Home position return acceleration time constant (msec) *5 0 600 300 150 600 300 150 1000 500 250 800 400 200 Different from the initial value. *5.
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
Valve model Type of actuation Port size 1 4/2 (P A/B) Flow characteristics Note 2) Note 3) Effective area mm2 4/2 5/3 (A/B EA/EB) Weight (g) Pilot port size Cv C [dm3/ (s bar)] b Cv C [dm3/ (s bar)] b Grommet Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 48
C J G5-S CV Fig. (6) Piping MVGQ Before connecting the pipes, remove any foreign matter.