Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
cable Flat ribbon cable (26P) with 3.0 m cable Flat ribbon cable (26P) with 5.0 m cable D-sub connector (25P) without cable D-sub connector (25P) with 1.5 m cable D-sub connector (25P) with 3.0 m cable D-sub connector (25P) with 5.0 m cable SI unit: EX126 IP65 compliant 1 to 12 stations (24) 1 to 12 stations (24) SDVB 1 to 8 stations (16) CC-Link T L kit (Lead wire) M kit (Terminal block
B PPS Non-leak (106 Pam3/sec), Medium vacuum (0.1 Pa.abs), Oil-free M FKM FKM V C37 Note) The leakage amount (10 6 Pam 3/sec) for the V and M option are values when the differential pressure is 0.1 MPa. 5
Nil T F N Rc NPTF G NPT Refer to page 43 for ordering coil only. Suffix Oil-free Nil Z Electrical entry Select Nil because the solenoid valve V, M options are oil-free treatment. G-Grommet C-Conduit Port size Refer to Table (1) shown below for availability.
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: S (Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: L (Light)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: L (Light)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: L (Light)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: L (Light), Bracket: B (Bracket)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: L (Light), Bracket: B (Bracket)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: D (BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: S (Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 2 (Energized Closed/N.O.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Bracket: B (Bracket)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: E (Brass or BC6, Copper Body & Shading Coil, EPR Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: E (Brass or BC6, Copper Body & Shading Coil, EPR Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: C (Conduit)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Q (Stainless Steel Body & Shading Coil, PTFE (FPM) Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: C (Conduit)