 
(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Grommet typeConnector typeCompliant with CE marking
(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Grommet typeConnector typeCompliant with CE marking
(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Grommet typeConnector typeCompliant with CE marking
(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Grommet typeConnector typeCompliant with CE marking
(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.8 00: ZM ejector mount type40 g (Including 0.6 m-Long lead wire)Grommet typeConnector typeCompliant with CE marking
(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Grommet typeConnector typeCompliant with CE marking
Because the piston cycle vibration is transferred, use the following retaining bolts (VBA1: M5; VBA2, 4: M10) and tighten them with the specified torque (VBA1: 3 Nm; VBA2, 4: 24 Nm). If the transmission of vibration is not preferred, insert an isolating rubber material between a product and the mounting surface. 2.
(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Grommet typeConnector typeCompliant with CE marking
Test data available upon request. 40-140'F (5 -60"C) Non relieving type (Standard), 'Relieving type (NSR1101, NSR1, NSR3101, NSR3111, NSR4101, NSR4111) only applicabl icr N2 gas or air HolIY TO ORDER F luid / Diaphrag m M aterinl a I allvt size M5-10-32Nom(t!
S Valve K Air supply valve/Vacuum release valve Thread type Nil T F Rc NPTF G How to Order Ejector Manifolds ZZMA 06 06 R Mixed mounting is possible with vacuum ejector series ZM.
V114-5LU Fluid Air Ambient and operating fluid temperature(oC) -10 to 50 (No freezing) Response time [ms] ON5 or less OFF4 or less Minimum operation frequency [Hz] 20 Lubrication Non-lube Mounting orientation Free Impact resistance/Vibration resistance (m/s2) 15030 Enclosure rating Dustproof Model No.
S Valve K Air supply valve/Vacuum release valve Thread type Nil T F Rc NPTF G How to Order Ejector Manifolds ZZMA 06 06 R Mixed mounting is possible with vacuum ejector series ZM.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: ø4 One-touch Fitting, Straight Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -