4 0 4 0 10.5 7 10 6.5 40 10 10 14 14 7.5 7.5 7.5 7.5 7 7 4 4 4 4 10.5 10.5 10 10 50 11.5 10.5 15.5 14.5 9 8 9 8 8.5 7.5 5.5 4.5 5.5 4.5 12 11 11.5 10.5 63 12.5 11.5 16.5 15.5 10 9 10 9 9.5 8.5 6.5 5.5 6.5 5.5 13 12 12.5 11.5 80 17.5 14 21.5 18 15 11.5 15 11.5 14.5 11 11.5 8 11.5 8 18 14.5 17.5 14 100 17.5 15 21.5 19 15 12.5 15 12.5 14.5 12 11.5 9 11.5 9 18 15.5 17.5 15 (mm) Auto switch model
EDS Enable 1 (SC_MonSs) Disable -10..10 V -5..5 V -20..20 mA 0..10 V 2 (Range) -10.. 10 V 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary PLC 3 (D_Format) Sign & Magnitude 2S Complement 2 None 2 2AVG 2 4 (Filter) 4AVG 4 8AVG 8 Enable 0.5 5 (Over_Rng) Disable Enable 0.5 6 (Undr_Rng) Disable 1 Enable (Upr_Lmt) 2 7 Disable 1 Enable (Lwr_Lmt) 2 8 Disable 1 2DeviceNet
49 1/8 17 8 32 M12 x 1.75 11 depth 6.5 61 51 10 18 14 15 7 47 6.6 63 1/4 19.5 10 40 M16 x 2 14 depth 8.6 65 55 10 22.4 19 20 7 52 9 71 1/4 20.5 10 50 M20 x 2.5 17.5 depth 10.8 71 60 11 28 24 24 8 58 11 81 1/4 22 10 63 M27 x 3 20 depth 13 80 67 13 35.5 30 33 9 69 13 97 1/4 25.5 10 80 M30 x 3.5 23 depth 15.2 95 78 17 45 41 36 14 86 15 117 3/8 30 15 100 M39 x 4 26 depth 17.5 122 96 26 56 50
For Water Digital Flow Switch Series PF2W How to Order Integrated Display Type PF2W7 20 03 27 M Flow rate range Thread type 04 20 40 11 0.5 to 4 L/min 2 to 16 L/min 5 to 40 L/min 10 to 100 L/min Unit specifications Nil N F Rc NPT G With unit switching function Note1) Fixed SI unit Note2) Nil M Lead wire (Refer to page 322.)
1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/
, SiC 10, Carbon 10, PP 10 3-phase 380 to 415VAC(50/60Hz) Allowable voltage range 10%(No continuous voltage fluctuation) Power supply 3-phase 460 to 480VAC(60Hz) Allowable voltage range +4%,-10%(Max. voltage less than 500V and no continuous voltage fluctuation) Rated current A 40 Electrical system Applicable earth leakage breaker Sensitivity current mA 30 Rated operating current 5 A 22 Rated
550 10 to 300 Parallel Stroke 701 to 800 20 to 550 12 to 330 6 to 180 24 to 750 16 to 500 8 to 250 30 to 750 20 to 550 10 to 300 range 801 to 900 24 to 610 16 to 410 8 to 200 30 to 750 20 to 550 10 to 300 901 to 1000 24 to 500 16 to 340 8 to 170 30 to 750 20 to 520 10 to 250 1001 to 1100 30 to 660 20 to 440 10 to 220 1101 to 1200 30 to 570 20 to 380 10 to 190 Max acceleration/deceleration
Bore size 4 6 10 16 Allowable Kinetic Energy(J) 0.7510 1.210 -2 2.510 -2 5.010 -2 -2 (Supply pressureat P=0.7MPa) 10 16 10 1 Load weight (kg) 4 6 0.1 0.01 10 100 1000 Maximum drive speed (mm/s) 18 Lateral Load at Rod End Caution In principle, the load applied to the piston rod should always be kept in the axial direction.
-1 10 1 IDX-OM-W014 10 M 10-2 ADM200 IDU3E6E-10-M IDU3E6E-20-M IDF-S0087 IDF-S0090 1.0MPa 1 1 2 / AC100V(50/60Hz) AC200V(50/60Hz) 4W IDU Series 10-2 10 2 IDX-OM-W014 10 M 10-3 Rc1/2 32 25 1) 2830Nm 30 (5) (17)(30) 2 2 Rc1/2 10-4 1-1 IDU Series 10-3 10 3 IDX-OM-W014 11 R 11 R 11-1 11-2 1 AC100V AC200V, AC230V INOUT IDU3E/4E/6E-10-R IDU3E/4E/6E-20/23-R (A)
2 pcs. 10 10 25 to 5 20 15 5 1 pc. 10 10 25 CXTl25 5 15 10 10 2 pcs. 10 15 20 CXTl 32 40 5 15 10 5 1 pc. 10 10 20 (mm) D-F7lW D-J79W D-F9BAL D-F7NT D-F79F Auto switch model D-A7l D-A8l D-A73C D-A80C D-A7lH D-A80H D-F7l D-J79 D-F7lV D-J79C Applicable model D-F7lWV D-A79W D-F7LF Number of mountings 2 pcs. 5 10 15 15 20 20 25 CXTl 32 40 1 pc. 5 5 10 15 15 20 25 3.8-10 Platform Cylinder Series
Model Maximum allowable load mass Average speed Va (mm/s) A2 10 11 12 17 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 0.6 1 2 4 Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Note) 16 mm for MXF8-10 only. 0.7 Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model Stroke (mm) 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98 2.22 3.41 6.66
thread (mm) A B C D E F G H J K M P Q R S L Bore size (mm) 20 9.5 depth 5.4 51 43 8 12 10 M8 x 1.25 10 6 30 5.5 43 1/8 16.5 6 11.5 25 9.5 depth 5.4 53 45 8 14 12 M10 x 1.5 12 6 36 5.5 49 1/8 17 8 12 32 11 depth 6.5 66 56 10 18 14 M12 x 1.75 15 7 47 6.6 63 1/4 19.5 10 19.5 40 14 depth 8.6 75 65 10 22.4 19 M16 x 2 20 7 52 9 71 1/4 21.5 10 21.5 50 17.5 depth 10.8 81 70 11 28 24 M20 x 2.5 24
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with
A2 10 11 12 17 Model A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 Graph (2) Allowable Moment Coefficient: Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Allowable Moment Coefficient: Note) 16 mm for MXF8-10 only. 0.7 Stroke (mm) Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model 10 0.56 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98
Outlines of Product 7 2.1 Features 7 2.2 How to Order 8 2.3 Product configuration 9 2.4 Start up procedure 10 (1) Checking the contents of the package 10 (2) Mounting the controller 10 (3) Controller Setting 10 (4) PLC set up 10 (5) Wiring and Connection 10 (6) Supply of power 11 (7) Setting parameters 11 (8) Setup of the operation parameters 12 (9) Test run 12 3.
-1 Signal and style of connectors -10-1 Table 10-2 Power Supply Cable -10-2 Abbreviations Abbreviation (The order of ABC) Meaning AC Alternating Current AT Auto Tuning Chap.
MPa) Operating direction Bore size (mm) 0.7 0.5 0.3 2015 11 6 IN 6 20 14 8 OUT Data 46 33 20 IN 10 55 39 24 OUT 121 86 52 IN 16 141 101 60 OUT Standard Stroke Bore size (mm) 6, 10, 16 Standard stroke (mm) 5, 10, 15, 20, 25, 30 Refer to Minimum Stroke for Auto Switch Mounting on page 8-3-10.
, 10, 16 Standard stroke (mm) 5, 10, 15, 20, 25, 30 Refer to Minimum Stroke for Auto Switch Mounting on page 8-3-10.
Give adequate confirmation, and then determine a model, just because the compatibility list shows the general case. 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump
4 A 2 A Power supply (Output) 24 VDC +10/-5%, 24 VDC +10/-5%, 8 A DC24 V +10/-5%, 4 A 2 A Enclosure IP67 (With manifold assembled) 1 Environment Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85%R.H.