G F C P J M N H K O L mm A B C D E F G H J K L M N O P IDFC60 R1 307 745 605 161 405 681 71 330 704 355 126 94 46 12.5 IDFC70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDFC80 R2 438 957 863 169 480 958 219 78 100 11.0 463 916 485 170 IDFC90 13 mm IDFC80 IDFC90 IDFC60 745 957 () () 704 916 () 355 () 330 485 463 IDFC70 890 () 849 () 390 365 IDFC60/70/80/90 Series 7-3 IDX-OM-W095
Stations: 02 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting
Stations: 02 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting
Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation
Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: JK (with Unit Options J & K), 1st Nominal Nozzle Size: 0 (for
Stations: 07 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation
Supply Valve and Release Valve: K (N.C.
), 1st Selection Supply Valve and Release Valve: K (N.C.
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting
Stations: 06 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: JK (with Unit Options J & K), 1st Nominal
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: JKW (with Unit Options J, K, & W), 1st
, 1st Nominal Nozzle Size: 1 (ΓΈ0.7), 1st Selection Supply Valve and Release Valve: K (N.C.
Response time (ms) Model Power consumption Flow rate Max. operating frequency Saving energy and continuous energization required ON OFF SX1-D 4 W 50 L/min 350 Hz 1.25 0.4 Select the 4 W type.
H D Hysteresis The difference between the OFF state and ON state value at a given setpoint value. Detection range Distance at which an instrument such as the Air Catch Sensor is operational. Hysteresis mode Refer to Technical Information on page 16-13-8.
Output impedance: 1 k Bring the pressure back to atmospheric pressure and try using the zero out function. Residual pressure error Brown DC(+) Black OUT (Analog output) + 12 to 24 VDC Load Blue DC() Supply pressure exceeds the maximum regulating pressure. -28 Analog output type 4 to 20 mA (2.5% F.S.)
S) D H VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN A port LVC 2-G LVA LVH SMC LVD SMC (J) C LVQ LQ E LVN TI/ TIL PA F K B port E PAX PB A B C D E F G H J K S LVN20 LVN30 LVN40 Model 48 60 72 2.4 7.5 8.0 18 24 30 20 26 33 14 25 25 4 5 6 6 9 11 34.5
L O L ZX G H F K ZR J ZM ZH E D I A ZU B C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZL 2-4.5 ZY ZQ A B C D E F G H I J K L Model 4 ZFC100-04 ZF 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 ZP 1/4" ZFC101-07 6 ZFC200-06 ZCU 8 ZFC200-
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: DL (with Manifold Options D & L), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver