How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33.3, Closed Dimension L2(mm): 19.3, Type: [Main Body] Body, Operation Method: Single Acting Type (Normally Closed), Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): -, Gripping Force (Open Side at 0.5 Mpa)(N): 83, Environment, Applications: Standard / Dust Resistant
Table 7-1 Water Quality Standards Substance Facility water Circulating water spec. spec. pH (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max.50 Sulfate ion (mgSO42-/L) Max. 200 Max.50 Acid consumption (pH4.8) (mgCaCO3/L) Max. 100 Max.50 Total hardness (mgCaCO3/L) Max. 200 Max.70 Calcium hardness (mgCaCO3/L) Max. 150
Trace the arrow mark, starting from F for cooling temperature 77F (25C) (pressure dew point 77F (25C)) to obtain the intersection G on the pressure characteristic line for 102psi (0.7 MPa). 8. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical axis. 9.
Note 9) Required flow when a load is applied as shown in the cooling capacity when the facility water teperature is at 25C.
Circulating fluid:Water (Circulating flow rate 3.96 gpm (15 L/min), Set temperature 77F (25C), Facility water temperature 77F (25C), Facility water flow rate 1.32 gpm (5 L/min), Ambient temperature 77F (25C) Note 2) For the compatibility between the circulating fluid and materials, refer to Applicable Fluids.
Note 2) Conditions: Set temperature 77F (25C), Facility water temperature 68F (20C), Facility water flow rate 2.1 gpm (8 L/min), Ambient temperature 77F (25C). Note 3) Conditions: Set temperature 77F (25C), Facility water temperature 68F (20C), Facility water flow rate 2.6 gpm (10 L/min), Ambient temperature 77F (25C).
reference), 3% F.S. (15 to 35C, 25C reference) Note 2) Without lead wire.
Repeatability (25C) 0.15% F.S. Absolute accuracy (25C) 0.5% F.S. 0.6% F.S.
), 3% F.S. or less (15 to 35C, based on 25C) Note 2) Without lead wire.
Note 2) Determined under the following conditions: water as the recirculating fluid, set temperature 77F (25C), facility water temperature 77F (25C), flow rate 0.8 gpm (3 L/min), ambient temperature 77F (25C), and sealed from outside air with a lid. Note 3) Differs depending on the operating conditions. Note 4) An appropriate range is from 0.8 to 1.3 gpm (3 to 5 L/min).
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Tap Water (as a Circulating Fluid) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water Item Unit Standard value Influence Corrosion Scale generation Voltage pH (at 25C) 6.0 to 8.0 v v Electric conductivity (25C) [mS/cm] 100*1 to 300*1 v v Chloride ion (Cl) [mg/L] 50 or less v Sulfuric acid
Servo motor (24 VDC) 77F = 25C, 104F = 40C Ambient temperature: 25C or less Ambient temperature: 40C LEY16Am Pushing force [%] Duty ratio [%] Continuous pushing time [min.]
Basic conditions Supply dew point: 20C (Atmospheric pressure dew point) Supply pressure: 0.5 MPa Ambient environment: 25C, 40% Fig.1 Verification Chart of Condensation (a) Find the correction factors.
Finger Stroke: L (Long Stroke), Bore Size: 12mm, Action: D (Double Acting), Finger Material: Carbon Steel, Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M
Finger Stroke: L (Long Stroke), Bore Size: 16mm, Action: D (Double Acting), Finger Material: Carbon Steel, Dust Cover: F [Fluoro Rubber (FKM)], Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Finger Stroke: L (Long Stroke), Bore Size: 20mm, Action: D (Double Acting), Finger Material: Carbon Steel, Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Finger Stroke: L (Long Stroke), Bore Size: 25mm, Action: D (Double Acting), Finger Material: Carbon Steel, Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)