106 2 2.3 3.2 6 7 10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 108 155 221 13 16 19 20 22 25 1/4, 3/8 3/8, 1/2 1/2, 3/4 1in = 25.4mm 5 Series AMP Model Selection Selection Caution Caution 1.
Note 4) q Ambient temperature: 25C, w Circulating fluid temperature: 20C, e Rated circulating fluid flow rate, r Circulating fluid: Clear water, t Facility water temperature: 25C Note 5) Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temperature is 10C or less.
M8 x 1.25 16 21 97 140 20 12.5 55.5 32 32 50 4 4.5 3 6 M8 x 1.25 16 22 97 102 140 20 6 11 49 40 40 66 5 6 4 8 M10 x 1.5 20 24 50 106.5 118 161 25 9.5 21 64 50 80 5 6 4 8 M10 x 1.5 20 24 63 106.5 118 161 25 4.5 16 59 63 End lock mechanism dimensions MGPL (ball bushing)/A, DB, E dimensions (mm) (mm) E A HN (Max.)
5 q u o Material Note Parts list !
Note 6) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.) Note 7) : For thread type, NPT only.
Note 6) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.) Note 7) : For thread type, NPT only.
Pad side q u Description Component Parts Material Surface treatment No.
(Light ON) One auto switch One position, either q or w, can be detected. Detection combinations Two auto switches Two positions q and w can be detected. How to determine auto switch installation position Step 1) Position fingers for gripping a workpiece. Step 1) Fully open the fingers.
Example)AC30-F03DM-KSTV-13NR-A q r t y w e q Symbol Bodysize Description 20 25 30 40 Rc NPT G Nil N F Threadtype w + 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 Portsize e + Floattype autodrain a Withoutautodrain N.C.(Normalclose)Drainportisclosedwhenpressureisnotapplied. N.O.(Normalopen)Drainportisopenwhenpressureisnotapplied.
Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) 3 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Circulating uid ow rate: Rated ow, t Power supply: 200/400 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200/400 VAC 5 q Ambient
5) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200 VAC, u Piping length: Shortest Note 6) When circulating uid outlet port pressure return port pressure = 0.25 MPa.
Note 5) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200/400 VAC, u Piping length: Shortest Note 6) With the pressure control mode by inverter.
Symbol 16 mm 22 mm Pilot port position Application Example Cleaning equipment 5 6 Position Symbol q w e r Applicable tubing size Nil 2 3 4 Applicable series LVP5 Tubing outside diameter 22 mm 26 mm 32 mm Symbol 16A 20A 25A Refer to the above.
RoHS How to Order [Option] Q R06 L PS 00 10 Option (CE-compliant ) Nil Q None CE-compliant Output specifications 10 11 12 For positive pressure For vacuum and residual pressure For vacuum The PS1200 series is CEcompliant (with Q) only.
VNH1 VNH2 VNH3 VNH4 VNH1-16 VNH2-16 VNH3-16 VNH4-16 Description Bracket (With bolt and washer) B How to Order Pilot Solenoid Valves VO307 1 Q D 5 CE-compliant Nil Q CE-compliant Rated voltage 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz Light/surge voltage suppressor CE-compliant 3 110 VAC 50/60 Hz D DIN terminal DZ DIN terminal with light/surge voltage suppressor 4 220 VAC 50/60 Hz 5 24 VDC 6
LER LEH LECP6 Series LECA6 Series How to Order LE C P 6 N Caution [CE-compliant products] q EMC compliance was tested by combining the electric actuator LE series and the controller LEC series. The EMC depends on the conguration of the customers control panel and the relationship with other electrical equipment and wiring.
No code 0 V3 L 1 H 2 4 No gauge port No pressure gauge Ports -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa Code Ports 2 ports 3 ports 2PW 3PW Porting Configuration e w q w q 1) Other range available.
Description Housing Outside tube Body Flower fin tube assembly Material Note SGP, SS400 STK FC200 C1220T Flower fin Flower fin q w e r q w e r Water chamber cover FC200 t AFF AM Replacement Parts Replacement Parts Misc. HAW22 HAW55 HAW75 HAW37 HAW110 No. Description HAW2 HAW7 Material No.
AS1200-M3 AS1400-M3 AS120-M5 AS220-01AS220-02 AS320-03 AS420-04 10-32UNF Port size M3 x 0.5 2.5, 4, 6 1.05 MPa 0.7 MPa 0.1 MPa M5 x 0.8 1/8 1/4 20, 25, 32, 40 3/8 1/2 6, 10, 15, 20, 25 80, 100 32, 40, 50, 63 Applicable cylinder bore size (mm) 1.5 MPa 1 MPa 0.1 MPa Proof pressure Max. operating pressure Body swivels 360 Swivel type allows free setting of piping.