Size: 25, Motor Mounting Position: R (Right), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type),

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length for LEC:

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 50mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length for LEC: 3

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length for

Size: 25, Motor Mounting Position: R (Right), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length for LEC

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length for LEC: 1 (1.5m),

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type)

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: D (Double Clevis), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: A (10m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length

, Size: 40, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 700mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: AP

Driver type Driver mounting AN Pulse input type (NPN) AP Pulse input type (PNP) Nil Screw mounting D Note) DIN rail mounting Note) DIN rail is not included. Order it separately. I/O cable length [m] Nil None 1 1.5 3 3* 5 5* Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16B-100 for the LEFS16B-100B-R1AN1D.

Controller/Driver type1 I/O cable length [m]1 Controller/Driver mounting Nil Without controller/driver 6N LECP6/LECA6 (Step data input type) NPN 6P PNP 1N LECP12 (Programless type) NPN 1P PNP AN LECPA2 (Pulse input type) NPN AP PNP Nil Without cable 1 1.5 3 32 Nil Screw mounting D DIN rail mounting DIN rail is not included.

MJ LECPMJ2 3 LEPY LEPS (CC-Link direct input type) AN LECPA2 4 (Pulse input type) NPN AP PNP !2 I/O cable length [m]1, Communication plug !

[Conversion piping set/ Conversion bypass piping set] [Mounting base adapter] [Piping adapter] IDF AP 601 Applicable to the IDF22E and 37E. Applicable to the IDF6E to 15E1. Select Conversion Piping Set when bypass piping is already in place, and Conversion Bypass Piping Set when there is no bypass piping. Part no.

Min. bending radius 45.5 mm 18 EX600-W Series u Power Supply Cable with M12 Connector (A-coded) EX500-AP 050 S Connector specification Cable length (L) 010 1000 mm 050 5000 mm S Straight A Angle Straight connector type Angle connector type M12 14.9 14.9 1 M12 5 1 2 2 6 6 28.3 5 4 3 4 3 30 5 50 40.7 27 30 5 50 L 25.3 Socket connector Socket connector pin arrangement pin arrangement L A-coded