SMC Corporation of America
Elite Part Number Search
Search Results "HRSE024-A-23"

When a filter element is used repeatedly, clean it with air blow or wash it with a neutral detergent. (For 40 m, For 80 m) Check the condition of the element and replace the element with a new one when the specifications are not satisfied.

IDX-OM-W011-B / Series IDF1E/2E/3E-10(-A,C,S) IDF3E-20(-A,C) IDF4E-10(-A,C,L,M,R,S,T) IDF4E-20(-A,C,L,M,R,T) IDF6E-10(-A,C,K,L,M,R,S,T) IDF6E-20(-A,C,K,L,M,R,T) IDF8E-10(-A,C,K,L,M,R,S,T) IDF8E-20(-A,C,K,L,M,R,T) IDF11E-10(-A,C,K,L,M,R,S,T) IDF11E-20(-A,C,K,L,M,R,T) IDF15E1-10(-A,C,K,L,M,R,S,T) IDF15E1-20(-A,C,K,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded

A One-touch fittings KP series B Dimensions (mm) Model A B C SFE4G 6 68.5 16.5 SFE5H 8 79 20.5 SFE7J 10 89 24 Bracket SFE-BR3 14 5 3.4 (15.5) 12.5 5.4 5.4 14 24 (20) SFE-BR4/5/7 B C (J) H D (F) G A E E Dimensions (mm) Model A B C D E F G H J SFE-BR4 30 16 7 4.5 7.5 (24.5) 17 15.5 (19.5) SFE-BR5 30 10 8.2 4.5 8.1 (29) 20 18 (23) SFE-BR7 34 14 7.35 4.5 9.8 (35) 24 20 (27.3) ( ): Reference dimensions

DC+COM A(-) C(+) COM B(-) 1N.C.ON 2 ZNR/ 3AB 23 - No.ZB-OM00301 (10ms ) 1 210ms 2 330m/s 4() A-C ON B-C ON N.C. A-C ON OFF 10msec ON 10 A B OFF 50 A B 10 1 50 3 3 24 - No.ZB-OM00301 ZB / / Assy /HNBR Assy //HNBR 25 - No.ZB-OM00301 2 ()() 5kPa () ZFAZFBZFC ON ZB1-VQ110U N.C (0.3 0.4 0.5 0.6) ZB1-VQ110L (0.30.4) ZB1-VQ120U N.C ZB1-VQ110N.C.

Turn cover A counterclockwise until it stops (approx. 45). 4. Install a new element on cover A and insert it into the case. Cover A Case Cover A Case O L L Element O-ring Window 5.

Do not apply a lateral load to the external slider. When a load is mounted directly to the cylinder, variations in the alignment of each shaft center cannot be offset, which results in the generation of a lateral load that can cause malfunction.

Tightening torque: 0.7 to 0.8 Nm 1 2 3 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Tightening torque: 0.7 to 0.8 Nm 1 2 3 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Soft Start-up Valve A V2000/3000/4000/5000 New New Series AV5000 introduced!

When installing a paddle on IF3O type, piping may be interfered with by the tip of a paddle. Because this is used to detect a small flow rate, and to narrow the distance between a paddle and piping, additional machining of the paddle tip may be necessary to eliminate interference between the two. 6. Use pipe fittings that comply with JIS specifications.

Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Please consult with SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire. Please consult with SMC regarding use in this kind of environment. 15-17-8

Released Workpiece 1 Workpiece 2 Workpiece n Atmosphere A B 4 Max. A: Max. pressure value when a workpiece is adsorbed. ON = A A B 4 Min. B: Min. pressure value when a workpiece is not adsorbed. OFF = B + 16-2-21 8 Series ZSE40/ISE40 Calibration Procedures Auto Preset (In the case of confirming the supply pressure) 1. Auto preset mode 2. Preparation for auto preset 3.

Display the option screen and check the LogMonitor. (21) The Log Monitor window is displayed on the main screen. (22) -11No.EX-OMV1026-B When scanning or IP address setting is performed, the processed information is displayed as a log. (23) Enter a keyword to Filter the log, and click the Filter button.

M Applicable tubing b Applicable tube a B A Reducer: M-32R-2, M-04R-2 Applicable tubing O.D. x I.D.

Press Part A by hand for temporary fixing. Press in the central part of Part A vertically with a tool such as pliers. A sensor connector cannot be taken apart for reuse once it is crimped. If the wire arrangement is incorrect or if the wire insertion fails, use a new sensor connector.

(A cylinder with 4 bore has been added as a compact type to the existing CJ2: 6 double acting cylinder.)

EXH : Exhaust Combination with a modular style FRL is possible.

A counter clockwise until it stops (approx. 45). 4) Install a new element on cover A and insert it into the case.

20 18 t 268 217 t 20 18 t 8x23 8x19 A A 8x23 8x19 20 4x 75 A 1056 A 720 9351 1290 160 150 150 160 t K K K K K16K JIS 80A 10K 64 (17) 17) 40 (K16K) 1823) (18~23) JIS 80A 10K 479 127 1332 1432 1,3 -W4 (-W4) -W4 Y3/4 (-W4) Y 3/4 () () R3/4 R3/4 20 50 165 475 9902 1030 950 (-W5) -W5 1,3 (-W5) -W5 R3/4 R3/4 IDF100F150F-W 6 5 IDX-OM-Z004 6 6.4 IDF100/125F/150F-30-W R

Do not apply a lateral load to the external slider. When a load is mounted directly to the cylinder, variations in the alignment of each shaft center cannot be offset, which results in the generation of a lateral load that can cause malfunction.