Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 1 PT, AIRLINE EQUIPMENT, AN SILENCER, HB, AN 1 INCH STANDARD (PT), .43503 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 1) These valves can be used without lubrication. 2) If a lubricant is used in the system, use class 1 turbine oil (no additives), ISO VG32. For details about lubricant manufacturers brands, refer to the SMC website.
IFW5 10 03 N 1 1 PSE Z I SE3 Diaphragm style flow switch PS Light 0 None Z I SE1 2 1 With neon light (110 VAC, Red) 2 With neon light (110 VAC, Green) Flow range ZSP 3 With neon light (220 VAC, Red) Low flow setting possible (1 l/min) 10 1 to 10 l/min 4 With neon light (220 VAC, Green) 20 10 to 20 l/min Simple flow setting Without removing the cover, you can set with a screwdriver from
Contact SMC representative for the applicable grease. 9/10 9-1. Model Selection 1 10/10 9-2.
L/min 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% Temperature characteristics (25C reference) 3% F .S. (15 to 35C) 5% F .S. (0 to 50C) 2% F .S.
Settings can be copied to up to 10 slave sensors at once. (Max. transmission distance: 4 m) Unit 1 Unit 2 Unit 10 1) The sensors are connected by a dedicated lead wire (ZS-38-5L (for master and one slave) or ZS-38-U (for master and up to 10 slaves)).
(C) 55 50 60 70 80 IDU3D to 6D 45 50 55 65 75 IDU8D to 15C 45 50 55 65 70 IDU22C1, 37C1 40 45 50 55 60 IDU55C, 75C Ambient temperature (C) Outlet air pressure dew point (C) 15 10 5 15 10 5 15 10 5 15 5 10 5 15 10 1.35 1.35 0.60 1.35 1.35 0.60 1.35 1.35 0.60 1.35 0.60 1.35 0.60 1.35 1.35 25 1.35 1.05 0.50 1.35 1.05 0.50 1.35 1.10 0.50 1.35 0.60 1.20 0.55 1.35 1.25 30 1.25 0.95 0.45 1.25 0.95
MTS Leakage [Pam3/sec] 10-8 MY Note 2) The leakage test result shown is based on a test conducted for 10 minutes after the cylinder was pressurized with helium at 0.1 MPa. CY Note 3) This data is considered typical but not guaranteed. 10-9 MG Leakage test result CX 10-10 0 5 10 DTime [min] -X e e a a l l k k w w a a 2 o o g g 1 O-ring seals separate vacuum and atmosphere.
Also, BBA2 is included when an auto switch alone is shipped.
Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 5, 10, 15, 20, 25, 30 20, 25, 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 50, 63, 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50 Intermediate strokes are available as a special order.
If it is pulled off at an angle, the pilot valve may be damaged or the protective O-ring may be scratched. 10 VQ4000V-OMV0001 VQ4000/5000 series Specific Product Precautions 3 Be sure to read this before handling the products.
Install an air filter. Check if the connections are correct after completing all wiring. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 or smaller. 4. External force applied to the lead wire If an excessive force is applied to the lead wire, this may cause faulty wiring.
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as valves.
Model Maximum allowable load mass Average speed Va (mm/s) A2 10 11 12 17 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 0.6 1 2 4 Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Note) 16 mm for MXF8-10 only. 0.7 Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model Stroke (mm) 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98 2.22 3.41 6.66
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
Free Free E Free Pitch dimensions (without magnet) (mm) Bore Size E 4 6 8 10 10 13 13 13.5 Free Easy seal replacement With front boss (h9) Seals can be replaced easily by removing rod cover. Centering can be done easily. Rod cover Tolerance h9 Clean room series Series 10-, 11-CUJ Two auto switches can be installed even for 4mm strokes.
With spring washer Adapter plate Note) Please contact SMC when using an individual EXH spacer assembly, an individual or an adapter plate assembly on VV5Z5-21P .
1.9 34 4.5 0.61 11 250 1.0 6 1.05 19 3 8 (10A) 8 1.7 31 340 0.4 10 2.4 43 (15A) 10 2.4 43 1 2 420 Note) Refer to p.4.0-14 the glossary for detail of max. operating pressure differential and max. system pressure.
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as valves.